background image

©2010  The Genie Company 

12/2010

14

SET

PROGRAM

Open 

Travel

Button

ROUND

LED Indicator 

(Light)

Facing

Garage Door

LONG

LED Indicator 

(Light)

Close

Travel

Button

 OVERVIEW OF POWERHEAD CONTROLS

This section describes the simple programming 
functions.  Use this page to familiarize yourself with the 
buttons and LED indicators used to program the opener.

NOTE: 

These   and   buttons are for programming use 

only.  Do 

NOT

 use these buttons to operate the opener. 

PROGRAM

SET

+

To garage door

FIG. 4-1   Locate programming buttons

FIG. 4-2   Programming buttons

There are three programming buttons and two lights 
(LEDs) on the powerhead.

Each of the buttons are used to enter and complete 
the setup programming.  The LEDs indicate status or a 
function change by illuminating ON, OFF, or ON 

flashing

 

in one of three different colors: BLUE, RED, or PURPLE.

Throughout the instructions in this manual the buttons 
and LEDs are also displayed as icons.

Buttons

Name Shape 

Use

Program button  

PROGRAM

SET

   Enters into and selects  

 

 

  programming menus

Close Travel button  

    multi-function;  

 

 

 

   moves door, advances  

 

 

   through menus

Open Travel button  

    multi-function;  

 

 

 

   moves door, advances  

 

 

   through menus

LED Colors

Round Red  

   and      Long Red

Round Purple  

   and      Long Purple

Round Blue  

   and      Long Blue 

Programming Overview

There are four Powerhead program menus:

Remote Program (Default menu)

Limits Program

Speed Program*

Force Program*

Programming steps for Limits and remotes are found on 
pages 6 through 10.
*Force and Speed settings are set at the factory and do 
not normally require adjustment programming.  Custom 
programming instructions for Speed and Force are 
located in the Troubleshooting Section of this manual.

These are the basic steps to enter into the four 
programming menus:

1.

 Press 

PROGRAM

SET

 and hold until both BLUE lights come ON 

then release.

2.

  Both LEDs go out and Round BLUE light comes 

ON.  You are in the Program Menus at the Remote 
Programming.

 

By using the   or the   button you can navigate to 
the Limits, Speed, or Force program menus and the 
LED display will change accordingly.

 

Each program menu has a specific LED display.

Press  

Program  

LED Display

 Default

   Remote  

Round Blue 

 

    

Limits

 Long 

Blue 

 

     X2 

Speed  

Round Blue 

 &   Long Blue

     X3 

Force  

Round Red 

 

3.

 Press 

PROGRAM

SET

 button to enter into the program menu 

functions.

 

If you have entered into an unwanted program menu 
and are not sure where you are - do not press any 
buttons for 30 seconds.  The programming function 
will time out after 

30 seconds

 if there is no key stroke 

activity.

4

Programming 
buttons location 
on powerhead.

Содержание IntelliG 1200 4024

Страница 1: ...WARNING To reduce the risk of injury to persons or damage to property Use this opener only with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOM...

Страница 2: ...ion which if NOT avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if NOT avoided could result in death or serious injury CAUTION indicates a pot...

Страница 3: ...imits and force and program new remotes Automatic Lighting System Two bulb lighting system supplies up to 200 Watts of light for safer evening exits and entries Turns ON when door is activated and aut...

Страница 4: ...learing Memory 15 IntelliCode Features 16 Previously Installed Openers 16 6 Maintenance Troubleshooting 17 26 Important Safety Instructions 17 Routine Monthly Maintenance 18 Door Balance SpringTension...

Страница 5: ...assemblies and other hardware before installing the opener 3 Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener 4 Where possible install th...

Страница 6: ...ns to open or close door A CLOSE DOOR TRAVEL LIMIT NOTE You can start and stop door movement using either buttons until door is in correct open or closed position Watch door move PROGRAMMING LIMITS FO...

Страница 7: ...9 SET FORCE SET FORCE Force is set automatically with first full CLOSE OPEN door operation 7 8 9 10 Perform a successful CONTACT REVERSE TEST and then continue with remote programming NOTE To reset LI...

Страница 8: ...6 7 and repeat steps 1 through 10 to correct down limit Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit Return to pages 6 7 and repeat steps 1 t...

Страница 9: ...s preset for use with the IntelliCode 2 Access Security System Refer to page 16 for additional information on IntelliCode 1 and 2 remotes and how to switch from IntelliCode 2 to IntelliCode 1 See page...

Страница 10: ...1 remote PRESS the same button and RELEASE SEE both LEDs on the powerhead come ON Blue The next press of the remote will operate door Test Repeat as necessary for any other IntelliCode 1 remotes Geni...

Страница 11: ...rieur du rail Cadena o correa ubicada dentro del riel Carriage Slide located inside rail Coulisse du chariot situ l int rieur du rail Deslizamiento del carro ubicado dentro del riel o carril Bullet B...

Страница 12: ...ring of power supply to opener must be installed by a licensed electrician Power cord must reach grounded outlet without use of extension cord Le c blage direct de l alimentation d nergie l ouvreur do...

Страница 13: ...COM INSTALLATION TYPIQUE D UNE PORTE DE GARAGE D UNE PI CE POUR OBTENIR DE L AIDE 1 800 35 GENIE INSTALACI N HABITUAL DE PUERTA DE UNA SOLA PIEZA PARA OBTENER AYUDA LLAME AL 1 800 35 GENIE FIG 3 2 WAR...

Страница 14: ...und Red and Long Red Round Purple and Long Purple Round Blue and Long Blue Programming Overview There are four Powerhead program menus Remote Program Default menu Limits Program Speed Program Force Pr...

Страница 15: ...death 1 Keep people clear of opening while door is moving 2 Do NOT allow children to play with opener including wall console remote or wireless keypad 3 During programming the door opener could begin...

Страница 16: ...um of 3 different openers can be programmed to a 3 button remote Programming remote to previously installed IntelliCode 1 Genie garage door openers Remotes provided with this unit can operate other In...

Страница 17: ...nt toute utilisation desdits metteurs Sendeger te entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir bernehmen keine Gew hrleistung f r die Einhaltung...

Страница 18: ...available Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly Safe T Beam STB SYSTEM CHECK STB Red and Green LEDs ON steady system OK STB Red LED flashes Check for o...

Страница 19: ...ner Open powerhead light cover Remove light bulb s Replace with maximum 100 Watt light bulb s Do NOT use light bulbs with greater than 100 Watt rating Close powerhead light cover 2 Reconnect power to...

Страница 20: ...e Lock Press and release to turn Sure Lock OFF OPTIONAL DUAL WALL CONSOLE INSTALLATION Use only a Series III wall console when adding a second wall console The optional second Genie Series III wall co...

Страница 21: ...ail rest on rail Do NOT overtighten Is there rust on chain or frayed edges on belt Contact a trained door system technician for chain belt replacement Are there kinks or twists in the chain or belt Co...

Страница 22: ...Press PROGRAM SET on the powerhead and hold until both lights turn steady ON Release button Lights go out and Round BLUE light comes ON 2 Press two times and the Round BLUE and Long BLUE lights come O...

Страница 23: ...quires no adjustment for normal operation Never increase the door closing force to compensate for a damaged door or a binding door track Never adjust force to compensate for a broken door spring Perfo...

Страница 24: ...ly set See pages 6 7 Check if Safe T Beam Red LED is flashing See page 18 Check Safe T Beam system for beam obstruction or misalignment of lenses See page 18 Check garage door for binding If an operat...

Страница 25: ...r system technician ON RED STEADY ON RED STEADY Limits NOT set properly Reprogram Limits see pages 6 7 ON RED FLASHING ON RED FLASHING Program error Unplug unit wait 5 seconds plug in Component failur...

Страница 26: ...CONECTADOR WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE WHITE BLANC BLANCO WHITE BLANC BLANCO BLACK NOIR NEGRO RED ROUGE ROJO BLACK NOIR NEGRO STRIPED WHITE BLANC RAY BLANCO RAYADO WALL CONSOL...

Страница 27: ...sales or repairs or maintenance to door components ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUL...

Отзывы: