ADJUSTMENT GUIDE 

- FORCE SETTINGS 

FOR HELP-1-800-35-GENIE OR WWW.GENIECOMPANY.COM

Force settings are pre-programmed at the factory 
and "learned" during the Open/Close Limit settings 
steps.  Some additional Force may be increased.  
For normal use, Force settings should not need 
adjustment with this unit.
However, conditions that might suggest an 
adjustment is necessary are;

Doors with very stiff weather seals.
Doors that start down, then STOP and reverse 
before they close.
Doors that start up, but STOP before they 
completely open.

Force Level

Powerhead LEDs

Round LED

Long LED

Default LED display is the 

current

 Force setting

LED indicator colors                                       

 OFF,  

 Blue,  

 Purple,  

 Red

Force Level LED indicator colors

Force Level 1

Blue

ON

 

 

OFF

Force Level 2

OFF

 

 

Blue

ON

Force Level 3

Blue

ON

 

 

Blue

ON

Force Level 4

Purple

ON

 

 

OFF

Force Level 5

OFF

 

 

Purple

ON

Force Level 6

Purple

ON

 

 

Purple

ON

Force Level 7

Red

ON

 

 

OFF

Force Level 8

OFF

 

 

Red

ON

Force Level 9

Red

ON

 

 

Red

ON

 

CAUTION

 

Door closing force is FACTORY set and requires no 
adjustment for 

normal

 operation.

•  Never increase the door closing force to 

compensate for a damaged door or a binding 
door track.

•  Never adjust force to compensate for a broken 

door spring.

•  Perform monthly CONTACT REVERSE TEST as 

described on page 18.

CHANGE FORCE SETTING

Use this guide to ADJUST powerhead FORCE settings.

NOTE: 

There are nine (9) force levels. 

1.

 Press 

PROGRAM

SET

 on the powerhead and hold until both 

lights turn steady ON.  Release button.  
Lights go out and Round BLUE light comes ON.

2.

 Press   

three

 times, Round RED light comes ON. 

3.

 Press 

PROGRAM

SET

 once to enter the Force Programming 

menu.  The round LED will flash BLUE 3 times, 
then the 

current

 Force setting 

for UP force

 will 

display on the LEDs.  See table below.

4.

  (If current UP Force setting is good, skip to Step 

5.)  Press   to increase or   to decrease 

UP Force 

settings

 within the available range. 

5.

 Press 

PROGRAM

SET

 to 

set 

UP Force level

.  The long LED will 

flash BLUE 3 times, then the 

current

 Force setting 

for DOWN force 

will display on the LEDs.

6.

  (If current DOWN Force setting is good, skip to 

Step 7.)  Press   to increase or   to decrease 

DOWN Force settings

 within the available range. 

7.

 Press 

PROGRAM

SET

 to 

set

 

DOWN Force level.

 Both LEDs flash 

BLUE to confirm.

Содержание IntelliG 1200 4024

Страница 1: ...WARNING To reduce the risk of injury to persons or damage to property Use this opener only with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOM...

Страница 2: ...ion which if NOT avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if NOT avoided could result in death or serious injury CAUTION indicates a pot...

Страница 3: ...imits and force and program new remotes Automatic Lighting System Two bulb lighting system supplies up to 200 Watts of light for safer evening exits and entries Turns ON when door is activated and aut...

Страница 4: ...learing Memory 15 IntelliCode Features 16 Previously Installed Openers 16 6 Maintenance Troubleshooting 17 26 Important Safety Instructions 17 Routine Monthly Maintenance 18 Door Balance SpringTension...

Страница 5: ...assemblies and other hardware before installing the opener 3 Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener 4 Where possible install th...

Страница 6: ...ns to open or close door A CLOSE DOOR TRAVEL LIMIT NOTE You can start and stop door movement using either buttons until door is in correct open or closed position Watch door move PROGRAMMING LIMITS FO...

Страница 7: ...9 SET FORCE SET FORCE Force is set automatically with first full CLOSE OPEN door operation 7 8 9 10 Perform a successful CONTACT REVERSE TEST and then continue with remote programming NOTE To reset LI...

Страница 8: ...6 7 and repeat steps 1 through 10 to correct down limit Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit Return to pages 6 7 and repeat steps 1 t...

Страница 9: ...s preset for use with the IntelliCode 2 Access Security System Refer to page 16 for additional information on IntelliCode 1 and 2 remotes and how to switch from IntelliCode 2 to IntelliCode 1 See page...

Страница 10: ...1 remote PRESS the same button and RELEASE SEE both LEDs on the powerhead come ON Blue The next press of the remote will operate door Test Repeat as necessary for any other IntelliCode 1 remotes Geni...

Страница 11: ...rieur du rail Cadena o correa ubicada dentro del riel Carriage Slide located inside rail Coulisse du chariot situ l int rieur du rail Deslizamiento del carro ubicado dentro del riel o carril Bullet B...

Страница 12: ...ring of power supply to opener must be installed by a licensed electrician Power cord must reach grounded outlet without use of extension cord Le c blage direct de l alimentation d nergie l ouvreur do...

Страница 13: ...COM INSTALLATION TYPIQUE D UNE PORTE DE GARAGE D UNE PI CE POUR OBTENIR DE L AIDE 1 800 35 GENIE INSTALACI N HABITUAL DE PUERTA DE UNA SOLA PIEZA PARA OBTENER AYUDA LLAME AL 1 800 35 GENIE FIG 3 2 WAR...

Страница 14: ...und Red and Long Red Round Purple and Long Purple Round Blue and Long Blue Programming Overview There are four Powerhead program menus Remote Program Default menu Limits Program Speed Program Force Pr...

Страница 15: ...death 1 Keep people clear of opening while door is moving 2 Do NOT allow children to play with opener including wall console remote or wireless keypad 3 During programming the door opener could begin...

Страница 16: ...um of 3 different openers can be programmed to a 3 button remote Programming remote to previously installed IntelliCode 1 Genie garage door openers Remotes provided with this unit can operate other In...

Страница 17: ...nt toute utilisation desdits metteurs Sendeger te entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir bernehmen keine Gew hrleistung f r die Einhaltung...

Страница 18: ...available Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly Safe T Beam STB SYSTEM CHECK STB Red and Green LEDs ON steady system OK STB Red LED flashes Check for o...

Страница 19: ...ner Open powerhead light cover Remove light bulb s Replace with maximum 100 Watt light bulb s Do NOT use light bulbs with greater than 100 Watt rating Close powerhead light cover 2 Reconnect power to...

Страница 20: ...e Lock Press and release to turn Sure Lock OFF OPTIONAL DUAL WALL CONSOLE INSTALLATION Use only a Series III wall console when adding a second wall console The optional second Genie Series III wall co...

Страница 21: ...ail rest on rail Do NOT overtighten Is there rust on chain or frayed edges on belt Contact a trained door system technician for chain belt replacement Are there kinks or twists in the chain or belt Co...

Страница 22: ...Press PROGRAM SET on the powerhead and hold until both lights turn steady ON Release button Lights go out and Round BLUE light comes ON 2 Press two times and the Round BLUE and Long BLUE lights come O...

Страница 23: ...quires no adjustment for normal operation Never increase the door closing force to compensate for a damaged door or a binding door track Never adjust force to compensate for a broken door spring Perfo...

Страница 24: ...ly set See pages 6 7 Check if Safe T Beam Red LED is flashing See page 18 Check Safe T Beam system for beam obstruction or misalignment of lenses See page 18 Check garage door for binding If an operat...

Страница 25: ...r system technician ON RED STEADY ON RED STEADY Limits NOT set properly Reprogram Limits see pages 6 7 ON RED FLASHING ON RED FLASHING Program error Unplug unit wait 5 seconds plug in Component failur...

Страница 26: ...CONECTADOR WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE WHITE BLANC BLANCO WHITE BLANC BLANCO BLACK NOIR NEGRO RED ROUGE ROJO BLACK NOIR NEGRO STRIPED WHITE BLANC RAY BLANCO RAYADO WALL CONSOL...

Страница 27: ...sales or repairs or maintenance to door components ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUL...