Begin here after the opener's physical assembly 

and installation has been completed.  

There are no assembly or installation steps included in this manual.  Contact 

your Genie® Professional Dealer for an installation poster, if required, or visit 

www.geniecompany.com to download a PDF file. 

The following mechanical assembly tasks must be completed before continuing.

 Powerhead and rail are bolted to each other  (An illustration is shown on page 11)

Example illustrations of the following items are shown on pages 12 and 13

 Rail end is attached to a header bracket which is attached to the garage door header

 Powerhead is attached to a support frame suspended from the ceiling or ceiling joists

 Both pieces of door arms are assembled and are attached to the garage door

 Safe-T-Beam® sensors installed and wired

 Wall console installed and wired 

(Shown on page 20)

 Carriage is engaged to the chain or belt drive 

(An illustration is shown on page 11)

 Powerhead is plugged into an approved power outlet 

Begin programming by setting Limits (see next page.)

©2010     The Genie Company 

12/2010

5

IMPORTANT INSTALLATION INSTRUCTIONS

 WARNING: To reduce the risk of severe injury or death:

1.

  

READ AND FOLLOW ALL SAFETY, INSTALLATION 
AND OPERATION INSTRUCTIONS.  

(If you have 

questions or do not understand an instruction, call 
The Genie Company.)

2. 

 Install only on a properly balanced 

sectional

 or 

one piece

 garage door.  An improperly balanced 

door could cause severe injury.  Have a trained door 
system technician make repairs or adjustments to 
cables, spring assemblies, and other hardware 

before

 

installing the opener.

3. 

 Remove all ropes and remove or make inoperative all 

locks connected to the garage door before installing 
opener.

4. 

 Where possible, install the door opener 

7 feet or 

more above

 the floor.  For products having an 

emergency release, mount the emergency release 6 
feet above the floor.

5.

  

Do NOT

 connect the opener to source of power until 

instructed to do so.

6. 

 Locate the wall console:

•  Within sight of the garage door,
•  At minimum height of 5 feet so small children 

are not able to reach it, and

•  Away from all moving parts of the door.

7. 

 Install the 

Entrapment WARNING Label

 next to the 

wall console in a prominent location.

8. 

 After installing the opener, the door must reverse 

within 2 seconds when it contacts a 1-1/2 inch high 
object (or a 2 x 4 board laid flat) on the floor.

INFRARED PROTECTION FUNCTION

1.

  When garage door is opening, its movement will not be influenced if the Safe-T-Beam® is 

obstructed.

2.

  If the Safe-T-Beam® is obstructed before the garage door fully closes, the door will not close.

3.

  When the garage door is closing, if Safe-T-Beam® is interrupted by person or obstacle, the garage 

door will stop its downward travel and reverse automatically to its fully opened position.

4.

  Remove Safe-T-Beam® obstruction.

5.

  If the Safe-T-Beam® System fails, loses power, or is installed improperly, press and hold the wall 

console "open/close" button until the door reaches its fully closed position.  If you release the 
"open/close" button on the wall console during the closing movement the door will reverse 
automatically to its fully opened position.

A PDF VERSION INSTALLATION POSTER IS AVAILABLE AT WWW.GENIECOMPANY.COM
OR CALL 1-800-35-GENIE

 

TO OBTAIN AN EMAIL PDF FILE

Содержание IntelliG 1200 4024

Страница 1: ...WARNING To reduce the risk of injury to persons or damage to property Use this opener only with a one piece or sectional door SAVE THIS MANUAL FOR FUTURE REFERENCE INSTALLER LEAVE THIS MANUAL WITH HOM...

Страница 2: ...ion which if NOT avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if NOT avoided could result in death or serious injury CAUTION indicates a pot...

Страница 3: ...imits and force and program new remotes Automatic Lighting System Two bulb lighting system supplies up to 200 Watts of light for safer evening exits and entries Turns ON when door is activated and aut...

Страница 4: ...learing Memory 15 IntelliCode Features 16 Previously Installed Openers 16 6 Maintenance Troubleshooting 17 26 Important Safety Instructions 17 Routine Monthly Maintenance 18 Door Balance SpringTension...

Страница 5: ...assemblies and other hardware before installing the opener 3 Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener 4 Where possible install th...

Страница 6: ...ns to open or close door A CLOSE DOOR TRAVEL LIMIT NOTE You can start and stop door movement using either buttons until door is in correct open or closed position Watch door move PROGRAMMING LIMITS FO...

Страница 7: ...9 SET FORCE SET FORCE Force is set automatically with first full CLOSE OPEN door operation 7 8 9 10 Perform a successful CONTACT REVERSE TEST and then continue with remote programming NOTE To reset LI...

Страница 8: ...6 7 and repeat steps 1 through 10 to correct down limit Stops after contacting the 2 x 4 board and does not reverse it may need an adjustment to the down limit Return to pages 6 7 and repeat steps 1 t...

Страница 9: ...s preset for use with the IntelliCode 2 Access Security System Refer to page 16 for additional information on IntelliCode 1 and 2 remotes and how to switch from IntelliCode 2 to IntelliCode 1 See page...

Страница 10: ...1 remote PRESS the same button and RELEASE SEE both LEDs on the powerhead come ON Blue The next press of the remote will operate door Test Repeat as necessary for any other IntelliCode 1 remotes Geni...

Страница 11: ...rieur du rail Cadena o correa ubicada dentro del riel Carriage Slide located inside rail Coulisse du chariot situ l int rieur du rail Deslizamiento del carro ubicado dentro del riel o carril Bullet B...

Страница 12: ...ring of power supply to opener must be installed by a licensed electrician Power cord must reach grounded outlet without use of extension cord Le c blage direct de l alimentation d nergie l ouvreur do...

Страница 13: ...COM INSTALLATION TYPIQUE D UNE PORTE DE GARAGE D UNE PI CE POUR OBTENIR DE L AIDE 1 800 35 GENIE INSTALACI N HABITUAL DE PUERTA DE UNA SOLA PIEZA PARA OBTENER AYUDA LLAME AL 1 800 35 GENIE FIG 3 2 WAR...

Страница 14: ...und Red and Long Red Round Purple and Long Purple Round Blue and Long Blue Programming Overview There are four Powerhead program menus Remote Program Default menu Limits Program Speed Program Force Pr...

Страница 15: ...death 1 Keep people clear of opening while door is moving 2 Do NOT allow children to play with opener including wall console remote or wireless keypad 3 During programming the door opener could begin...

Страница 16: ...um of 3 different openers can be programmed to a 3 button remote Programming remote to previously installed IntelliCode 1 Genie garage door openers Remotes provided with this unit can operate other In...

Страница 17: ...nt toute utilisation desdits metteurs Sendeger te entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir bernehmen keine Gew hrleistung f r die Einhaltung...

Страница 18: ...available Unapproved or incompatible wall consoles can cause the opener to operate unexpectedly Safe T Beam STB SYSTEM CHECK STB Red and Green LEDs ON steady system OK STB Red LED flashes Check for o...

Страница 19: ...ner Open powerhead light cover Remove light bulb s Replace with maximum 100 Watt light bulb s Do NOT use light bulbs with greater than 100 Watt rating Close powerhead light cover 2 Reconnect power to...

Страница 20: ...e Lock Press and release to turn Sure Lock OFF OPTIONAL DUAL WALL CONSOLE INSTALLATION Use only a Series III wall console when adding a second wall console The optional second Genie Series III wall co...

Страница 21: ...ail rest on rail Do NOT overtighten Is there rust on chain or frayed edges on belt Contact a trained door system technician for chain belt replacement Are there kinks or twists in the chain or belt Co...

Страница 22: ...Press PROGRAM SET on the powerhead and hold until both lights turn steady ON Release button Lights go out and Round BLUE light comes ON 2 Press two times and the Round BLUE and Long BLUE lights come O...

Страница 23: ...quires no adjustment for normal operation Never increase the door closing force to compensate for a damaged door or a binding door track Never adjust force to compensate for a broken door spring Perfo...

Страница 24: ...ly set See pages 6 7 Check if Safe T Beam Red LED is flashing See page 18 Check Safe T Beam system for beam obstruction or misalignment of lenses See page 18 Check garage door for binding If an operat...

Страница 25: ...r system technician ON RED STEADY ON RED STEADY Limits NOT set properly Reprogram Limits see pages 6 7 ON RED FLASHING ON RED FLASHING Program error Unplug unit wait 5 seconds plug in Component failur...

Страница 26: ...CONECTADOR WHITE BLANC BLANCO BLACK NOIR NEGRO GREEN VERT VERDE WHITE BLANC BLANCO WHITE BLANC BLANCO BLACK NOIR NEGRO RED ROUGE ROJO BLACK NOIR NEGRO STRIPED WHITE BLANC RAY BLANCO RAYADO WALL CONSOL...

Страница 27: ...sales or repairs or maintenance to door components ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICUL...

Отзывы: