AutoVu SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016
36
•
E
: Securing screws
Example
Watch this video to learn more. Click the
Captions
icon (
CC
) to turn on video captions in one of the
available languages.
Related Topics
System status LEDs on the LPR Processing Unit
on page 74
Securing wires using tension clamp connectors
on page 31
Wire ferrules for a SharpX installation
When connecting the power port to the LPR Processing Unit in a SharpX installation, you can use the
ferrule crimping tool that is included with the AutoVu Alignment Kit to crimp a ferrule to the end of
each stripped wire for a more secure connection.
The following table shows the appropriate ferrules for each wire gauge:
Wire AWG
Ferrule color
14
Blue
16
Black
18
Red
20
Grey
24
Violet