61
Genesis LXP
®
© 2015 Genesis Attachments, LLC
Symptom
Possible Cause
Possible Solution
Does not rotate
Blown fuse
Replace fuse
Electrical problem
Test for 24V at plugs on directional valve
while depressing foot switch
Incorrect pressure settings
Set pressures
Faulty components
Contact Genesis to replace valve
Does not rotate in one
direction
No electrical power to one side
Test for 24V at plugs on directional valve
while depressing foot switch
Faulty directional control valve
Check if directional control valve shifts both
ways while actuating foot switch in both
directions
Faulty cartridge
Contact Genesis to replace valve
Rotator chatters
Electrical short
Test for continuity through circuit
Low supply flow
Back out flow controls
Pressure settings too high
Set pressures
Supply flow too high
Reduce flow from excavator control valve
Power to both rotation solenoids at the same
time
Test for 24V at plugs on directional valve
while depressing foot switch
Rotates faster in one
direction
One flow control cartridge set higher than the
other
Set flow control
Rotates too fast or too
slow
Flow control out of adjustment
Set flow control
Rotation speed
changed from original
setting
Jam nut loosened on rotation flow control
valve
Check jam nuts on rotation flow control
valve; set pressures
Faulty cartridge (contamination)
Replace cartridge
Faulty directional control valve
Replace valve
Pressure set too low
Set pressures
ROTATOR TROUBLE-SHOOTING