20 Genesis LXP
®
© 2015 Genesis Attachments, LLC
OPERATION
Articulate processor body to engage jaw set.
•
Both left and right trunion pins must be seated in processor cradle.
•
Lock pin bore must be aligned with quick plate bore.
Once quick plate is aligned, hold processor cylinders’ retract lever and hit electric switch to extend
lock pin. Make sure both sides of lock pin are completely extended. Note: One side may fully
extend before other side begins to extend.
Shut off the machine.
Reinstall safety plates after the machine is shut off.
Slightly extend cylinders to ensure clearance at center formed plate in jaw set.
Articulate processor so one cylinder is vertical. Extend or retract cylinder to align with jaw bore.
Ensure bores are free of contaminates; install pin.
Repeat for second cylinder.
Grease cylinder pins, lock pins, and pivot group.
Open jaw and remove processor from stand. Cycle jaws several times to ensure change-over is
successful.
Note: Keep lock pin bores greased during storage.
JAW SET CHANGE-OVER
Safety Plate
Installing Cylinder Pins