OPERATION
Jaw set change-over requires at least one worker on the ground in addition to the operator. Use
basic safety precautions. All personnel on the ground must stand clear during operation.
Change-over Procedure:
Lower processor into stand. Lightly clamp jaw to middle plate.
Remove cylinder pins. Grease lock pin. Remove safety plates.
Retract cylinders.
•
While continuing to hold on processor cylinders retract lever (jaw open), hit electric switch
to retract lock pin.
•
Ensure both sides of lock pin have retracted. One side may fully retract before the other
begins to retract.
Articulate processor body to disengage jaw set.
Position processor body at new jaw set.
Check lock pin bores in new jaw set. Wipe bore clean to ensure there are no contaminants. Clean
quick plate trunion pins and mating “U” in processor body.
JAW SET CHANGE-OVER
Processor Body
Cylinder
Bore
Stand
Mating “U”
Cylinder
Quick Plates
Quick Plate Trunion