80
Englis
h
10.3 Fuel change from propane to gasoline or reverse
Fuel change from propane to gasoline or reverse can be performed while the
engine is on.
Change from Gasoline to Propane:
1. Keep the generator running and disconnect the devices from the generator.
2. Open the propane valve in the bottle regulator.
3. Turn the fuel selector switch quickly and without stopping at the "OFF"
position to the propane position (LPG). If you perform this step slowly the
generator could come to a halt when passing through the "OFF" position.
Change from propane to gasoline:
1. Keep the generator running and disconnect the devices from the generator.
2. Turn the fuel selector switch quickly and without stopping at the "OFF"
position to the GASOLINE position. If you perform this step slowly the
generator could come to a halt when passing through the "OFF" position.
3. Close the propane valve in the bottle regulator.
DANGER: In order to ensure safety, always make sure to
close the propane valve of the bottle when you have finished
using this fuel.
Содержание 401173
Страница 2: ......
Страница 51: ......
Страница 100: ......
Страница 149: ...145 Português ...
Страница 150: ...146 Português POLIGONO INDUSTRIAL NEINVER CALAHORRA LA RIOJA CONTACTO INFORMAÇÕES INFO SG GROUP ES ...