BACS WEBMANAGER Configuration

 

11 

12 

9  8 

10 

Alarm 
Contact 

 

Slot Version

 

 External Version  

External Version 
with integrated

 

BACS Bus Converter 

12 

 

BACSKIT_BSC4

 

 

BACSKIT_SCMB4

 

 

BACSKIT_LB4

 

 

BACSKIT_LMB4

 

 

BACSKIT_B4

 

Description

 

Function

 

1

 COM1 Port 

Connection with an UPS or another end device via the original RS232-cable. 

2

 COM2 Port 

Connection for optional devices like a modem, multi sensor SENSORMANAGER,  
temperature sensor, humidity, field busses (MODBUS, RS232, Profibus, LONBus, etc.).  

3

 LAN Port 

Ethernet 10/100 Mbit interface with integrated LEDs  
(green LED: connection to the network established, yellow LED: network-activity).  

4

 DC Input 

Power supply 12VDC/1A stabilized through external power supply,  
DC-connector inside (-) minus, outside (+) plus.  

5

 COM3/AUX 

For the connection to the BACS® Bus Converter (at BUDGET 4 internal),  
max.1m Rj12/6pole cable. 

 
6

 LEDs (red/green)  

Operation Status WEBMANAGER 

Red LED 

Green LED 

No Power 

  OFF 

  

OFF 

Booting 

  ON 

  

OFF 

Update in progress 

 

  

flashing slowly 

  

OFF 

Update failure 

 

  

flashing fast 

  

OFF 

UPS Communication lost 

 

ON 

  

OFF 

Operating 

  OFF 

 

 

flashing slowly  

7

 Slide Switch 

 

Alarm LED 

BACS-Alarm LED (green / red / yellow)  

9

 MUTE Button 

Button for the acknowledgement and mute of the horn. Alarm LED changes to yellow. 

10 

BACS Bus 

2 x Rj10 interface to connect   
BACS C-Module / SPLITTINGBOX / BACS_CSXXX / GX_R_AUX  

11 

BACS Service Port 

For connection to a PC/Laptop RS232-port, for addressing or readout the BACS modules via 
BACS_Programmer or BACS_Reader Software directly (provided RS232 cable - DSub9 -> Mini-
Din8) . 

12 

RS485 Interface 

MODBUS variants: BACSKIT_SCMB4 and BACSKIT_LMB4 

Toggles configuration and operation mode 

Slide Switch middle position: 

Sets the BACS® WEBMANAGER BUD-

GET to the configuration mode. After cold boot/reboot the default IP ad-
dress 10.10.10.10 is active.

 

Slide Switch right position: 

DHCP is activated and an IP address is set 

automatically. Check MAC address of your BACS WEBMANAGER to 
locate according IP Address.

 

Slide Switch left position: 

Sets operational mode 

 

Содержание BACS System

Страница 1: ...Components BACS Measuring Cable BACS Bus Cable BACS Module BACS WEBMANAGER CS141 SNMP Adapter Professional BACS Bus Converter BACSKIT_BSC4 Slot Version BACSKIT_LB4 External Box CS141 SNMP Adapter MODB...

Страница 2: ...with EN 50272 2 2001 Safety Re quirements for Secondary Batteries and Battery Installations Part 2 Stationary Batteries IEEE Standard 450 2002 Recommended Practice for Maintenance Testing and Replace...

Страница 3: ...s after a discharge period BACS modules must NOT be mounted on a damaged battery If a battery is damaged and its internal resistance is high charging current or current being discharged may follow the...

Страница 4: ...time frame for reaction to alarms BACS is a tool designed to increase the durability of accumulators but its most important function is to monitor the battery in order to avoid breakdowns For this rea...

Страница 5: ...ry the surface of the ac cumulator with an antistatic fabric 1 2 Installation BACS Measuring Cables Please follow the installation diagrams on the next pages to mount the cables correctly to the batte...

Страница 6: ...BACS test lead to all poles Note If the battery has more than 4 poles it is sufficient to connect the BACS cable to four battery poles Use the same poles at each battery Note Please refer to the batte...

Страница 7: ...Order No BACSC23 Order No BACSC30 Order No BACSC40 Order No BACSC41 Order No BACSC50 As standards BACS modules are equipped with integrated temperature Optional you can get the Module with an externa...

Страница 8: ...cooling ribs or plugs Wet cells For wet cells and low maintenance batteries ensure a clearance to the breather of at least 10 cm 3 94in BACS Modules with external temperature sensors Instead of the i...

Страница 9: ...e Velcro strips 2 Mounting the BACS module Position the BACS module press it firmly with your thumb under high pressure and hold the pressure for about 5 10 seconds Connecting BCx Measuring Cable to t...

Страница 10: ...maximum of 50 connected modules The modules can be connected to the bus in any order It is not necessary to connect the modules of the addresses in sequence Connection to the BACS WEBMA NAGER BACS Bus...

Страница 11: ...4 Max cable length from BACS WEBMANAGER to BACS SPLITTING BOX should not exceed 10m 395in Otherwise it will reduce the max length of 6 5 The cable length of the connection between the BACS SPLITTING...

Страница 12: ...en the distance of 50m 1970in 8 Max number of BACS Modules is 512 9 Max distance from BACS WEBMANAGER to BACS CURRENT SENSORs should not exceed 10m 395in 10 Max distance between the BACS_GX_R_AUX and...

Страница 13: ...ER MODBUS RS485 CS141SCM Slot external BACS Bus Converter Order No BACSKIT_SCMB4 SNMP WEB MANAGER MODBUS RS485 CS141LM external external BACS Bus Converter Order No BACSKIT_LMB4 The BACS Bus Converter...

Страница 14: ...generex us Wiring instruction BACS WEBMANAGER BACS WEBMANAGER BACS Kit Box with external BACS Bus Converter BACS Bus cables Power Supply BACS BUS Special cable RJ12 BACS BUS Power Supply Power Supply...

Страница 15: ...allows an optimized star shaped bus cabling instal lation It is possible to connect more BACS SPLIT TING BOX at one BACS System Distribute all BACS modules equally to the ports of the SPLITTING BOX E...

Страница 16: ...Converter BACS Buskabel BACS Bus cable BACS WEBMANAGER Budget with BACS SPLITTING BOX Installation of the BACS hardware complete For operational mode the BACS modules need to be configured BACS Bus ca...

Страница 17: ...12 6pole cable 6 LEDs red green Operation Status WEBMANAGER Red LED Green LED No Power OFF OFF Booting ON OFF Update in progress flashing slowly OFF Update failure flashing fast OFF UPS Communication...

Страница 18: ...PS cable to the COM1 port of the web manager Connecting the BACS WEBMANAGER directly with a UPS system is an additional feature BACS will run without it too when using a BACS WEBMANAGER Slot card vers...

Страница 19: ...141 snmp 2 4 Run the Setup Wizard On very first login the Webmanager will start a tool that will help you with the basic configuration System Setup Wizard The Setup Wizard will guide you through the m...

Страница 20: ...f you want to use BACS only select No UPS model defined 3 4 Press Apply to save your settings Configure the local system time The time is important for accurate event logging 1 Under System go to Date...

Страница 21: ...pply or insert the slot card into the according slot of the UPS 4 Connect the Webmanager to your local network The UPS will continue running as expected Remo ving the power supply from the external CS...

Страница 22: ...they are connected to the measuring cable They wake up automatically if the BACS WEBMANAGER BACS Programmer or BACS Reader sends request To wake up the modules it s necessary to activate bus communic...

Страница 23: ...er tap using a configuration like that you need to setup your BACS system according to it To handle different power circuits your BACS confi guration needs for each power circuit an indepen dent strin...

Страница 24: ...earch Tool Find BACS modules by address 4 2 1 Addressing BACS Modules via Automatic Mode Automatic mode allows automatic addressing of modules After each successful addressing an address is automatica...

Страница 25: ...can also press and hold the button on the relevant BACS module for about 10 se conds to reset the module to the delivery state With C20 HW 3 x FW 3 4 1 and C30 C40 HW 3 x from FW 3 4 2 this BACS modu...

Страница 26: ...to provide the replacement of broken mo dules as well as adding one single module to the existing configuration Please Ensure only one module is connected to your Manager Entering address Under Old en...

Страница 27: ...dialog as expected 1 Remove the power supply from the WEBMANAGER For the slot versions pull the card out of the slot of your UPS 2 To switch the WEBMANAGER to operating mode left position manual IP ri...

Страница 28: ...ccessful initialization the BACS status page will be displayed with the voltage and temperature of the batteries the equalization power and the status of the LEDs After approximately 15 minutes the fi...

Отзывы: