Page 17
Serial #10127003 and Later
HF SERIES
GENERAL PUMP
A member of the Interpump Group
Conclusion: with a wheelbase of 23.62 (600 mm) and with a dynomometer, loading the belt branch with 16.86 ft lbs
(75 N) as indicated in fig, a “te” bend of approximately 0.43 in (10.8 mm) is obtained.
Fig. 12
Lf = Wheelbase
te = Belt bend
Fe = 75 N Dynamometer load
Note 1 •
Unless otherwise stated by the supplier of the belts, control of proper pull and its relative re-tensioning should
be performed after no less than 30 minutes of motion necessary for the normal adjustment of the belts. Best perfor-
mance and durability will be achieved with proper tensioning.
Note 2 •
In case of necessity or for routine maintenance, never replace a single belt but the complete set.
9.13 Transmission of Power From the Second PTO
Upon request, HF series pumps can be supplied with an auxiliary PTO on the opposite side to the driver (transmission
of power from the second PTO).
Ref 300764 Rev. F
05-21