Electrical Specifications
(cont)
Recommend Three Wire Shielded Cable:
Maximum distance between the Model S216A and the
power source.
AWG
Feet
Meters
22
750
228
20
1100
335
18
1600
488
16
2250
685
14
4500
1372
For interfacing with 250 ohm input impedance devices,
the following maximum cable lengths apply, with
respect to the Analog Signal. The total loop resistance
can be no greater than 300 ohms.
AWG
Feet
Meters
22
1600
488
20
2400
730
18
3800
1160
16
5200
1585
14
9000
2740
NOTE
:
Good design practices dictate cable lengths
conservatively shorter than the maximum given
values.
5.1.4 Environmental Specifications
Operating Temperature Range:
-40°F to 140°F
(-40°C to 60°C)
Storage Temperature Range:
-31°F to 131°F
(-35°C to 55°C)
Humidity Range:
15 to 90% RH non-condensing
Enclosure:
Weather-proof rating : NEMA 4X