47
5.2.2 Receiver does not display startup sequence when power is
applied
-
Verify that the power supply is on and that it is set to 24 volts +/- 1 volt.
-
Verify that the wiring is correct.
-
Use a voltmeter to check the voltage at the wiring terminal, or remove
the unit and check it using a different supply.
5.2.3 Receiver displays ]-[ during alignment
-
Verify that the Source is aimed at the Receiver and that the Receiver is
aimed at the source.
-
Verify that the beam path from the Source to the Receiver is free of
obstruction.
-
On the Receiver and on the Source, with power removed from the
Source, verify that the window on each unit is clean and that an
attenuator is not in place.
5.2.4 Receiver displays F1 or F3 after alignment
-
Verify that the Source is aimed at the Receiver and that the Receiver is
aimed at the source.
-
Verify that the beam path from the Source to the Receiver is free of
obstruction.
-
On the Receiver and on the Source, with power removed from the
Source, verify that the window on each unit is clean and that an
attenuator is not in place.
5.2.5 Receiver does not respond to the magnet
-
Try a slightly different location for the magnet.
5.2.6 Receiver signal level number went to 0 with no “A” on the
display
-
Apply the magnet to resume alignment (The alignment mode times out
after 30 minutes)
-
Stack a second magnet onto the first.
5.2.7 Receiver displays information other than described
-
Refer to the IR5500 Receiver User Menu to apply the magnet and
resume alignment.
5.2.8 Source or Receiver will not move
-
Verify that fine adjust screw tops are flush with the assembly surface.
-
Verify that the two front mounting screws have not been tightened
down.
-
Verify that the nut at the bottom of the pan-tilt assembly has not been
tightened down.
-
Insert a large screw driver or rod between the bottom of the unit and the
mounting assembly. Press on it to loosen the mounting.