Model IR5500
33
4.5 Flash Input “in”
The flash input data is used to diagnose issues such as poor alignment, path interference, and aging
Source lamp.
The rSd is the relative standard deviation of reference flash input intensity. The rEF is the average
reference flash intensity. An rSd > 60 for ind time sets fault F12. An rSd
≤
60 resets fault F12. The
rSd and rEF values are updated every 30 seconds