SpectraComm 800 T3 Data Service Unit
4-1
Issue 4
Installation and Operation Manual
Chapter 4:
Diagnostics
Diagnostics Overview
This chapter provides detailed information on diagnostic tests on the SC 800 T3 DSU can be
initiated by the network manager via an SNMP controller, by the DTE via the HSSI port, or by the
network. Basic procedure for any diagnostic test is provided in Chapter 3.
Before You Begin
You should test the equipment when it is first installed to verify correct installation. After the
equipment is in service, use the diagnostic tests to diagnose any problems that occur in the operation
of the DSU or the data communications system. Applicable diagnostic tests are timed. The front
panel TM LED will illuminate for all tests.
lists each diagnostic test and how it can be initiated. Detailed information for each test,
including data path diagrams are provided after the table.
Note
The Remote Payload Loopback and the Remote Payload Loopback with Self Test are for C-Bit framing only.
Note
For information on initiating tests through GDC TEAM software, refer to the TEAM 800 T3 Manual.
Table 4-1
SC 800 T3 Diagnostic Tests
SC 800 T3 DSU Diagnostic Tests
Initiated via:
Master or Remote
DTE Loop
A/B Lead
SNMP
Control
Terminal
Interface
Local Loopback Test
Either
✔
✔
Local Loopback w/ Self Test
Either
✔
✔
Payload Loopback
Either
✔
✔
Line Loopback
Either
✔
✔
End-to-End w/ Self Test
Master only
✔
✔
Remote Line Loopback
Master only
✔
✔
✔
Remote Line Loopback w/Self Test
Master only
✔
✔
Remote Payload Loopback
Master only
✔
✔
Remote Payload Loop w/Self Test
Master only
✔
✔
DTE Loopback Test
Master only
✔
✔
✔