Safety
11
General dangers
Start-up is forbidden until it has been established that the product has
been set up and wired according to the EU guidelines for machinery.
Unauthorized modifications to the product exempt the manufacturer
from any liability from resulting damages or accidents.
The operator must ensure that all users do have the appropriate training
for powder spraying equipment and are aware of the possible sources of
danger.
Any operating method, which will negatively influence the technical
safety of the powder spraying equipment, is to be avoided.
For your own safety, only use accessories and attachments listed in the
operating instructions. The use of other parts can lead to risk of injury.
Only original Gema spare parts should be used!
Repairs must only be carried out by specialists or by authorized Gema
service centers. Unauthorized conversions and modifications can lead
to injuries and damage to the equipment and invalidate the Gema
Switzerland GmbH guarantee.
Electrical danger
The connecting cables between the control unit and the spray gun must
be installed in such a way, that they cannot be damaged during the
operation. Please observe the local safety regulations!
The plug connections between the powder spraying equipment and the
mains should only be removed when the power supply is switched off.
All maintenance activities must take place when the powder spraying
equipment is switched off.
The product may not be switched on until the booth is in operation. If the
booth stops, the product must switch off too.
Explosion hazard
The control units for the spray guns must be installed and used in zone
22. Spray guns are allowed in zone 21.
Only original Gema OEM parts are guaranteed to maintain the explosion
protection rating. If damages occur by using spare parts from other
manufacturers, the warranty or compensation claim is void!
Conditions leading to dangerous levels of dust concentration in the
powder spraying booths or in the powder spraying areas must be
avoided. There must be sufficient technical ventilation available, to
prevent a dust concentration of more than 50% of the lower explosion
limit (UEG = max. permissible powder/air concentration). If the UEG is
not known, then a value of 10 g/m³ should be considered (see EN
50177).
All unauthorized conversions and modifications to the electrostatic
spraying equipment are forbidden for safety reasons.
No safety devices should be dismantled or put out of operation.
Mandatory operational and workplace notices from the operating
company must be written in a comprehensible manner in the language
of equipment operators and posted in a suitable place.
Содержание OptiFlex Pro B Spray
Страница 5: ...Rev 00 03 19 OptiFlex Pro B Spray Table of contents 5 Diffuser OptiSelect 54 Pneumatic group 55 ...
Страница 6: ......
Страница 14: ...Rev 00 03 19 14 Safety OptiFlex Pro B Spray ...
Страница 22: ...Rev 00 03 19 22 Product description OptiFlex Pro B Spray ...
Страница 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro B Spray ...
Страница 48: ...Rev 00 03 19 48 Disposal OptiFlex Pro B Spray ...
Страница 51: ...Rev 00 03 19 OptiFlex Pro B Spray Spare parts list 51 OptiFlex Pro B Spray Spare parts fig 10 ...
Страница 56: ......
Страница 58: ...Rev 00 ...