Rev. 00 03/19
OptiFlex Pro B Spray
Operation
31
Setting powder output and powder cloud
The powder output depends on the selected powder output (in %), and
the powder cloud on the selected total air volume.
The AP01 Application pump should be operated with powder at
least 1/2 hour after starting up.
– After the running-in of the filter elements a stable powder output
value will be reached.
As a factory default value, a powder rate of 60% and a total air
volume of 4 Nm³/h are recommended.
– If values are entered that the gun control unit cannot implement,
then the operator is informed of this by a blinking in the relevant
display and a temporary error message!
Setting the total air volume
1.
Adjust the total air volume on the gun control unit with the
T3/T4
keys
– Adjust the total air volume according to the corresponding coating
requests
correct powder cloud
too little total air
Setting the powder output
1.
OR
Содержание OptiFlex Pro B Spray
Страница 5: ...Rev 00 03 19 OptiFlex Pro B Spray Table of contents 5 Diffuser OptiSelect 54 Pneumatic group 55 ...
Страница 6: ......
Страница 14: ...Rev 00 03 19 14 Safety OptiFlex Pro B Spray ...
Страница 22: ...Rev 00 03 19 22 Product description OptiFlex Pro B Spray ...
Страница 26: ...Rev 00 03 19 26 Assembly Connection OptiFlex Pro B Spray ...
Страница 48: ...Rev 00 03 19 48 Disposal OptiFlex Pro B Spray ...
Страница 51: ...Rev 00 03 19 OptiFlex Pro B Spray Spare parts list 51 OptiFlex Pro B Spray Spare parts fig 10 ...
Страница 56: ......
Страница 58: ...Rev 00 ...