SM32 • Instruction manual
75
Espaňol
Deutsc
he
Fr
ançais
Eng
lish
Italiano
6. Umrichterbetrieb
6.1. Beispiel für Klemmleistenanschluss
C
K1M
L1
L1
L2
L3
N
PE
5
1
3
24
6
5
F1
F2
1
2
3
4
6
70
72
OK Relay
UV
W
PE
U3
V3
CD
D
Q2
PE
PE
35
37
34
33
32
36
52
23
PRECHARGE
COMMAND
From 1050
size
Digital
output
Note
!
Fan with external supply
only from 1050A
size
and higher
MLP
ML
Precharge
enable
Common
MLP& ML
GND 24
Common
Precharge enable
24V
Power supply of
the MLand MLP
(*)
(*)
Sizes
SM32-480-185
SM32-480-280
SM32-480-420
SM32-480-650
SM32-480-1050
SM32-480-1500
SM32-480-2000
Fan qty
.
2
2
2
2
3
2
2
Fan type
24V / 4W (**)
24V / 5W
24V / 5W
24V / 12W
230V
AC / 0.6A
tot.
230V
AC / 0.4A
tot.
230V
AC / 0.4A
tot.
(**)
(**)
(**)
Cooling fan protection (F10)
6.3 x 32mm, 500V
, 1.6A
slow
6.3 x 32mm, 500V
, 1.6A
slow
(**) No connection is required, those internal fans are power supplied by an internal circuit.