50
ADV200 • Quick start up guide - Specification and installation
2
Description of the parameter.
3
Depends on the type of parameter:
●
Numeric parameter:
displays the numeric value of the parameter, in the
format required, and unit of measurement (
fi
gure A).
●
Binary selection:
the parameter may assume only 2 states, indicated as
OFF-ON or 0 - 1 (
fi
gure B).
●
LINK type parameter:
displays the description of the parameter set from the
selection list (
fi
gure C).
●
ENUM type parameter:
displays the description of the selection (
fi
gure D)
●
Command:
displays the method of execution of the command (
fi
gure E)
4
In this position, the following may be displayed:
●
Numeric parameter:
displays the default, minimum and maximum values
of the parameter. These values are displayed in sequence pressing the
►
key
(figure A).
●
LINK type parameter:
displays the number (PAR) of the parameter set (
fi
g-
ure C) .
●
ENUM type parameter:
displays the numeric value corresponding to the cur-
rent selection (
fi
gure D).
●
Command:
in the case of an error in the command, indicates that ESC must
be pressed to terminate the command (figure G).
●
Messages and error conditions
(figure F):
Param read only
attempt to modify a read-only parameter
Password
active
the parameter protection password is active
Drive enabled
attempt to modify a non-modi
fi
able parameter with the drive enabled
Input value too high
the value entered too high
Input value too low
the value entered too low
Out of range
attempt to insert a value outside the min. and max. limits
6.2.3 Scanning of the parameters
T+
T-
E
N
L
OC
ILim
n:
0
AL
01
M
ON
IT
O
R
02 D
RIVE I
N
F
O
03 S
TARTUP WIZAR
D
0
4
D
RIVE
CON
FIG
T+
T-
EN
L
OC
ILi
m
n:
0
AL
0 1
.
0 1
P
A
R
:
2 5 0
O
utput current
+
0 . 3
A
T+
T-
EN
L
OC
ILi
m
n:
0
AL
0 1
.
0 2
P
A
R
:
2 5 2
O
ut ut volta e
p
g
-
1
V
T+
T-
EN
L
OC
ILi
m
n:
0
AL
0 1
.
2 2
P
A
R
:
1
4
0 0
D
igital out ut X mon
p
0
. . .
. . .
6.2.4 List of the last parameters modi
fi
ed
Pressing the
CUST
key, a list containing the last 10 parameters modi
fi
ed is ac-
cessed. One parameter at a time is displayed and the list can be scrolled using
the
▲
and
▼
keys.
To exit this list, press the
►
key.
6.2.5 “Goto parameter” function
Pressing the
CUST
key twice, or once if already in the “List of modi
fi
ed param-
eters”, the “Goto parameter” is activated.