ADV200 • Quick start up guide - Specification and installation
137
10.3.3 Speed control limits
Speed range (*) _____________________± 32000 rpm
Speed format (*) _____________________32 bit
Frequency range _____________________± 2000 Hz
Max frequency ______________________FVCL: 300Hz, FVOL : 150 Hz, VF : 500 Hz (fsw
≥
4kHz)
FVCL: 200Hz, FVOL : 150 Hz, VF : 200 Hz (fsw = 2kHz)
Min frequency _______________________FVCL: 0Hz, FVOL : 0.5 Hz, VF : 1 Hz
(*) referred to Full scale speed, PAR:680.
10.3.4 Torque control
Torque resolution (*) _________________> 0.1 %
Torque regulation accuracy (*) __________FVCL : ± 5%
Direct torque control __________________yes
Current limitation ____________________Limits ±, Limits mot/gen, Limits variable
(*) referred to rated torque
10.3.5 Current rating
Heavy duty (HD) _____________________150% 60 sec, 180% 0.5 sec.
Light duty (LD) ______________________110% 60 sec.
Switching frequency mode (LD) __________
≤
160kW: 4 kHz, independent of SWF
≥
200kW: 2 kHz, independent of SWF
Switching frequency mode (HD) _________Constant : 2, 4, 6, 8, 10
(**)
, 12
(**)
kHz
Variable : 8, 4 kHz, function of temperature and output
frequency (up to size 90kW)
(**) Not available on 4450 and higher sizes.