ADV200 • Quick start up guide - Specification and installation
43
1
2
3
4
5
9
8
7
6
TxA/RxA
TxB/RxB
PE
+5 V
XS
Reserved
RS485
EQP
Figure 5.5.1.1: Serial connection (not insulated)
A twin-pair consisting of two symmetrical conductors, spiral wound with a common
shield plus the bonding connection cable, connected as shown in the
fi
gure, must
be used for connection. The transmission speed is 38.4 kBaud.
For connection of the RS485 serial line to the PC, see the
fi
gure below.
RS485
(XS)
RS485 RS232
PCI-COM
(S5T60)
Industrial PC
(with RS485)
RS232
USB
USB RS232 converter
(S5A20)
PC
with
RS232
port
PC
with
USB
port
RS485
(XS)
RS485
(XS)
RS485 RS232
PCI-COM
(S5T60)
Shielded cable with connectors,
5 mt (8S8F59)
Shielded cable with connectors,
5 mt (8S8F59)
Shielded cable with
connectors,
5 mt (8S8F59)
Kit (S50T6) = Shielded cable 5 mt + PCI-COM
Figure 5.5.1.2: RS485 connection to the PC
Connection of an industrial PC with RS485
The following are required for connection:
•
shielded cable for the
XS / RS485
connection (see
fi
gure 5.5.1.1), code
8S8F59
Connection to a PC with RS232 port
The following are required for connection:
• an
optional
PCI-COM
(or PCI-485) adapter, code S560T.
•
shielded cable for
XS / PCI-COM
(or PCI-485) connection, code 8S8F59, see
fi
gure 5.5.1.1 .
Connection to a PC with USB port
The following are required for connection:
• an
optional
PCI-COM