18
Y Series TechBook
--
Parameter
Display
Options
Description
Output 1
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 1
Output 2
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 2
Output 3
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 3
Output 4
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 4
Output 5
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 5
Output 6
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 6
Output 7
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 7
Output 8
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 8
Output 9
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 9
Output 10
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 10
Output 11
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 11
Output 12
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H, ON
Accessory connected to relay Output 12
Output 13
--,CP
Accessory connected to the Direct Output 1
Output 14
--,CP
Accessory connected to the Direct Output 2
Heater
--,H
Accessory connected to the heater relay
CP usage
CP Standard = 0
CP Always On = 1
Usage of the circulation pump
Ozone usage
Ozone with filtration = 0
Ozone Always On = 1
Usage of the ozone generator
Ozone Pump
Circulation pump = 0
Pump #1 = 1
Pump associated with the ozone generator
Ozone Type
Standard (UV) = 0
Timed (Corona) = 1
Type of ozone generator
Heater Pump
Circulation pump = 0
Pump #1 = 1
Pump associated with the Heater
Filter Config
Purge only = 0
With Circ Pump = 1
With Pump 1, Low speed = 2
Filter cycle configuration
Temp Units
°F = 0
°C = 1
Temperature units used on display
Clock Format
No time display = 0
AM/PM format = 1
24H format = 2
Clock display format
--
--
--
--
--
--
Table 1
--
In the event that none of the pre-determined low-level program configurations built in the unit's system suit your spa
equipment assembly, it's possible to custom configure the system by manually entering key parameter settings
To access this menu, press and hold
Prog
(or
Light
key) for 30 seconds Use
Up
or
Down
key to choose setting
Press
Prog
key (or
Light
key) to go to the next parameter
Y Series field programming options
--
--
--
--
--
--
--
-
-
-
-
-
-
-
-