40
Y Series TechBook
40
If the ozonator is not working,
follow this troubleshooting flow chart:
Step-by-Step
Ozonator doesn't work
/ flow chart & step-by-step
Has
Filter Cycle
indicator
appeared steady
on keypad
display?
yes
no
Start up a
filter cycle
yes
Do you read
120 V for a
120 V ozonator
(or 240 V for 240
V) on
the board?
Replace
ozonator
no
yes
Is Pump 1
working?
Replace spa pack
if you still aren’t
getting a voltage
reading
no
Refer to “
Pump 1
does not Work!
”
section
Flow chart
Ozonator output will be shut down when Pump 1, Pump 2 or blower have been turned on manually
If the ozonator is not
working:
•
Check if
Filter Cycle
indicator appears
steady on keypad
•
If the filter indicator
is blinking it indicates
that the filter cycle
has been interrupted
In that case, reset the
breaker by turning
the power off and
on again to resume
cycle
•
If not, start up a
filter cycle (see
Programming Filter
Cycles
section)
98
•
If you don't get a
voltage reading,
replace the accessory
fuse
•
If changing the fuse
does not fix the
problem, replace the
spa pack
•
If voltage is as it
should be, replace
ozonator
• If ozonator does not
work even when filter
cycle indicator is on,
take voltage reading
on the corresponding
AMP connector:
Pin 1 & Pin 3
Your reading should be:
240 V for
a 240 V pump
120 V for a
120 V pump
Pin 3
Pin 1
Ozonator fuse (F2)