14
Y Series TechBook
Programming the Y Series
using the keypad
Although every Y Series
spa pack is factory set,
in certain cases when
servicing or replacing a
new unit in the field, it
may be necessary to set
a new pre-determined
low-level program
configuration into the spa
pack
Follow these simple steps
to re-enter the low-level
programming menu using
the keypad:
Press and hold the
Pump 1
key for 30 seconds
98
Use the
Up/Down
key to
choose the new desired
low-level configuration
number and press the
Program
key to confirm
the selected configuration
(refer to the configuration
selection chart section in
this manual)
If the
Program
key is
not pressed within 25
seconds, the unit will
exit this menu without
changing any settings
If at power-up of the
system your keypad
display shows
the following message:
"L _ _ ",
it means that all
low-level configurations
have been downloaded,
but no configuration
number has
been chosen
Note: If the keypad in use
does not have the Program
key, use the
Ligh
t key instead.
The keypad display will
show
L xx
where
"xx"
represents the previous
configuration number
registered in the system
Remove the cover to
access the low-voltage
inlink connectors inside,
connect the instik to the
communications port (see
figure), and then re-apply
power to pack
At power-up the spa pack
will upload all the different
configurations from the
instik memory
The unit will then enter the
low-level configuration
menu
The keypad display will
show
L xx
where "
xx
"
represents the previous
configuration number
registered in the system
Use the
Up
/
Down
key to
choose the new desired
low-level configuration
number
Press the
Prog
key to
confirm the selected
configuration (see
configuration selection
charts)
If the
Prog
key is not
pressed within 25
seconds, the unit will
exit this menu without
changing any settings
Note: If the keypad in use
does not have the Prog key,
use Light key instead.
If, when the system
powers up, your keypad
display shows the
following message:
"L
_ _
",
it means that all
low-level configurations
have been downloaded,
but no configuration
number has
been chosen
Note: When programming is
finished, do not forget to turn
power off, remove the in.stik,
and re-install the pack’s cover.
Programming the Y Series
using the in.stik
This feature is very useful
on production lines to
configure packs and in the
field for service purposes
like software updates
Follow these simple
steps to upload new
pre-determined low-level
program configurations
into the spa pack
Shut electrical power off
Programming the Y Series
communications port