Warning!
Spring tension in the valve
Danger of injury when detaching the clamp connection (43.1) as the
released spring pretension will suddenly lift the actuator.
► Therefore, release the spring tension before detaching the clamp
connections by pressurizing the actuator with compressed air at max. 8 bar.
Carry out the following steps:
1.
Remove the cleaning connection (30).
2.
Air out the valve upon connection (22).
3.
Air out the valve upon connection (22).
®
The valve discs (15/16) are raised.
4.
Remove the snap ring (43.1).
5.
Interrupt the compressed air supply to the connection (22).
6.
Remove the half ring (49).
7.
Pull off the control top (B) upwards
®
Light-emitting diode A (green) will go out and light-emitting diode B will
flash yellow.
®
Done
10.5.2 Disconnecting the Valve from the Housing
Fig.11
Maintenance
Disassembling the Valve
430BAL008360EN_5
42
07.02.2022