Technical data: Ambient temperatures
Designation
Description
- Control top type T.VIS M-15, A-15
-20 to +50 °C (-4 ... +122 °F)
- Control top type T.VIS P-15
0 to +50 °C (-4 ... +122 °F)
Product temperature and operating
temperature
Depending on the sealing material
Technical data: Compressed air supply
Designation
Description
Air hose
- Metric
Material PE-LD outside Ø 6 mm
Inside Ø 4 mm
- Inch
Material PA outside-Ø 6.35 mm
Inside Ø 4.3 mm
Product pressure
5 bar (72.5 psi) standard
max. 10 bar (116 psi)
Control air pressure
6 bar, max. 8 bar
Control air
acc. to ISO 8573-1
- Solid particle content:
Quality class 6 max. particle size 5 µm
max. particle density 5 mg/m
3
- Water content:
Quality class 4 max. dew point +3 °C
If the unit is used at higher altitudes or
at low ambient temperatures, the dew
point must be adapted accordingly.
- Oil content:
Quality class 3, ideally oil-free, max.
1 mg oil for 1 m
3
air
5.3
Cleaning connection
Connection for the hose
1 ", DN 25
Ø6/4 mm
DN 40...100
Ø8/6 mm
1,5"...4" OD; 2"...4" IPS
Ø8/6 mm
DN 125, 150; 6" IPS; 6" OD
Ø10/8 mm
Service pressure for the optimal cleaning
•
min. 2 bar (29 psi)
•
max. 5 bar (72.5 psi)
Technical data
Cleaning connection
430BAL008360EN_5
24
07.02.2022