Malfunctions
Malfunctions
In the event of malfunctions immediately deactivate the control valve and secure it
against inadvertent reactivation. Malfunctions may only be remedied by qualified staff,
who must observe the safety instructions.
Malfunction
Cause
Remedy
Valve does not work
Fault in the control system
Check the system configuration
No compressed air
Compressed air pressure
too low
Check the compressed air supply
Check air hoses for free passage and
air tightness
Fault in the electrical
system
Check actuation and routing of elec-
trical lines
Valve disk blocked
mechanically
Clear the blockage
Stroke scanning lever has
shifted
Readjust the stroke scanning lever
Actuator not working
correctly as a result of the
control air being soiled
Check the control air quality
Replace the positioner
Diaphragm defective
Replace the diaphragm
Valve does not close tight
Dirt/foreign materials in the
valve housing
Clean the valve housing
Valve stroke too short as
air pressure too low
Check the compressed air supply
Leakage at the housings
O-ring/V-ring defective
Dismantle the valve housing, replace
the seals