Installation and Commissioning
Fitting the Valve with Detachable Pipe Connection Elements
26
Operating Instructions · Control Valve A
Edition 2016-06-07
Installation and Commissioning
Notes on Installation
GEA Tuchenhagen recommends that the valve should be installed vertically (actuator
up, housing bottom). If the control valve is not installed vertically, the stress on the valve
stem seals is higher than when installed vertically. Therefore, regularly check the control
valve for leakage.
To prevent damage, make sure that
•
the valve is installed in the pipe system free of tension and
•
no foreign materials (e.g. tools, bolts, lubricants) are left in the system.
Fitting the Valve with Detachable Pipe Connection
Elements
CAUTION
If pipes contain liquids, these can spurt out when the pipes are opened.
Danger of injury as a result of hot or aggressive liquids.
Before releasing any pipe or clamp connections, drain and, if necessary, clean or
flush the pipe.
Separate the pipe section in which the valve is to be fitted from the rest of the piping
system to prevent product entering again.
Carry out the following steps:
Fit the control valve directly into the pipe system using suitable connection fittings.
Done