2016-12 · GEA Hilge Kreiselpumpe TPS, selbstansaugend / Centrifugal Pump TPS, selfpriming · Version B
CAUTION
The 2 flush bores (S) must point in vertical direction so
that air can escape from the flush chamber.
CAUTION
Make sure that the shaft protection sleeve (110.1) is
pressed up to the limit stop of the shafts shoulder (7)
CAUTION
Make sure that the 2 drive pins in the slide ring (100.1)
catch into the relevant grooves of the impeller (1) with
integrated driver.
The sliding surfaces of the slide ring (100.1) and the
counter ring (100.2) must be free from grease.
Einfachwirkende Gleitringdichtung, gespült
QU (A)
Single-acting mechanical seal, flushed
QU (A)
VORSICHT
Die 2 Spülbohrungen (S) müssen sich in vertikaler Aus-
richtung befinden, damit die Luft aus der Spülkammer
entweichen kann.
VORSICHT
Darauf achten, dass die Wellenschutzhülse (110.1) bis
zum Anschlag der Wellenschulter der Welle (7) gepresst
ist.
VORSICHT
Darauf achten, dass die 2 Mitnehmerstifte im Gleitring
(100.1) in die vorgesehenen Nuten des Laufrades (1) mit
integriertem Mitnehmer greifen.
Die Gleitflächen von Gleitring (100.1) und Gegenring
(100.2) müssen fettfrei sein.
100.2
S
7
100.1
1
110.1
S
100.1
Detail: Einfachwirkende Gleitringdichtung, gespült
Detail: Single-acting mechanical seal, flushed
110.1
100.2
9