![GEA TPS Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/gea/tps/tps_operating-instructions-manual_572289020.webp)
18
2016-12 · GEA Hilge Kreiselpumpe TPS, selbstansaugend / Centrifugal Pump TPS, selfpriming · Version B
Malfunction, Cause, Remedy
CAUTION
In the event of malfunctions, immediately deactivate the pump and secure it against inadvertent reactivation.
Defects may only be rectified by qualified personnel observing the safety instructions.
Malfunction
Cause
Remedy
Motor does not start
No power supply to the motor
Switch off the pump, check cable connecti-
ons and fuse
Motor circuit breaker has tripped
Check the motor’s power consumption
M
otor circuit breaker or r.c.c.b. has tripped or
the fuses have blown, because cable, motor or
control devices are damaged
Measure the parts and repair or replace any
faulty parts
Switching device contacts faulty
Check the switching devices, dismantle,
clean and
replace any faulty parts
Motor power consumption
too high
Viscosity of the pumped medium too high
Check the pump system, throttle as required,
turn off impeller, change pump or motor
Gap between housing and impeller not set
correctly
Set gap
Resistance in the pressure pipe too low
(flow rate too high)
Check the pump system, throttle as required,
turn off impeller, change pump or motor
Impeller diameter too big
Fit a smaller impeller
Turn off the impeller
Too much noise
emission
(also cavitation)
Resistance in the suction pipe too high
Check the suction pipe, shorten or extend as
required
Liquid level in the suction tank too low
Fill the suction tank
Impeller scraping
Measure the axial gap and reset in accordance
with the chapter “Checking the axial gap”
Motor bearing damage
Replace the bearing
Mechanical seal running dry
Immediately switch off the pump, check the
mechanical seal, replace if required
Determine the cause of dry running and elimi-
nate the fault
Flow head or flow rate too
low
Motor rotates in the wrong direction
Reverse the phases
Motor speed too low (voltage, frequency not
correct); number of poles not correct
Apply the correct voltage
Replace the motor
Impeller diameter too small
Fit a larger impeller
Impeller worn
Replace the impeller
Too much resistance in suction and/or pressu-
re pipe
Check the pipes
Viscosity of the pumped medium too high
Check the pump system, fit a larger impeller
Pump leaking
Mechanical seal defective
Replace the mechanical seal
O-ring defective
Replace the O-ring
Pump not drawing in
liquid
No residual liquid in the pump
Fill the pump with a minimum of liquid
System not executed to specifications
Execute the system in accordance with specifi-
cations on suction and pressure sides