1.2.5
Foundation requirements
Hint!
Compressor (package) has to be mounted on a concreted block. On
request, Grasso can calculate the exact dimensions of the concrete
block, based on the compressor size and operating conditions.
This paragraph covers measures to be taken for a compressor (package)
mounting on a concrete block.
Two foundation arrangements are described:
1.
Compressor package with steel base frame mounted on a concrete block.
Following base frames are possible;
1.a
Frame designed for mounting on concrete block.
For more instalation details refer to; Section 1.2.5.1, Page 16,
Section 1.2.5.2, Page 17, Section 1.2.5.3, Page 18, Section ,
Page 19, Section , Page 19.
1.b
Frame designed for mounting on vibration dampers.
For more details in case mounting base frames on vibration dampers is
applied, refer to separate instruction sheet and other order
documentation like package drawing, supplied with the compressor
package and consult Grasso if required.
2.
Bare compressor direct mounted on a concrete block via grouted anchors.
For more installation details refer to; Section 1.2.5.1, Page 16,
Section 1.2.5.2, Page 17, Section 1.2.5.4, Page 19.
1.2.5.1 Concrete structure
Fig.4:
Concrete block
1
Cork board
2
Concrete base
3
(Concrete) Floor
4
Sand
The concrete block for compressor and motor or compressor package should
have a profile as illustrated in Page 16 and made according to the following
recommendations:
INSTALLATION AND PREPARATION FOR USE
INSTALLATION
0089288gbr_11
16
30.10.2017
Содержание Grasso V 1100
Страница 6: ...0089288gbr_11 6 30 10 2017 ...
Страница 8: ...0089288gbr_11 8 30 10 2017 ...
Страница 10: ...0089288gbr_11 10 30 10 2017 ...
Страница 61: ...Fig 16 Grasso V 6 Pre lubrication valve APPENDIX Product Information PI 0089288gbr_11 30 10 2017 61 ...