6
Contractor’s manual
F15 - F30 Generators
Manual For F15 and F30 - Mill.: 2008 - 11 / Mod.: JPM 05
Page
3.1 Safety rules
Starting and stopping a GENEGLACE.
Use the switch provided for this purpose on the electrical
terminal box.
CAUTION
When stopping, the rotating part of the generator
maintains a residual rotation that may cause an
accident.
If it is diffi cult to reach the Start/Stop switch (machine
mounted high up), request a remote control at a more
convenient height.
If it is necessary to switch the machine off, use the isolating
switch on the electrical terminal box (three phase). Lock
the equipment with a padlock on the isolating switch to
prevent inadvertent starting of the machine.
The principal area of danger is located inside the ice maker
itself, enclosed by an upper cover and a base cover.
It is dangerous to place the hands or any object into this
area while the rotating part is turning, for example during
a normal cleaning operation of the water system.
It is recommended that the machine be stopped and
switched off for cleaning or that the emergency switch on
the upper part is used.
If the rotating part is driven by a reduction gear and a
motor through a belt, a guard that can removed by using
tools is provided. Operation of the machine without this
guard is prohibited.
The operation of manual valves is strictly reserved for
maintenance personnel with the necessary skills (risk of
spurting of fl uids under pressure).
In the event of a general power failure, protect yourself
against any risk when the power returns (unintended start-
ing): keep personnel away from dangerous areas.
Operation of the machine without the original safety equip-
ment is prohibited: torque limiter, electrical protection,
pressostats, thermostats, transmission guards, etc. These
devices must be maintained in working condition and the
pictograms indicating the dangers must remain visible.
The drawing below indicates the principal dangerous
areas of the GENEGLACE.
3. Safety and Environmental Instructions
3.2 Protection of the Environment
Materials and fl uids resulting from the disposal of ma-
chines must be treated via the approved channels in
accordance with current regulations.
Safety and Environmental Instructions
Within the directives of the “MONTREAL PROTOCOL”,
any service work that might place the cooling system in
communication with the atmosphere must be performed
by skilled personnel.
The use of a mains socket or an upstream isolating switch
is prohibited.
Before operating, switch off the installation
Before operating, switch off the installation. All other
maintenance, if required, shall be done by a qualifi ed
engineer.