Fig.34
Requirement:
•
Only use solenoid valves specified in chapter “Technical data”.
Hint!
In order to avoid or minimize the possibility of damage from
electrostatic discharge:
- Observe the requirements of DIN EN 61340-2-1 and 5-2.
- Be careful not to touch the electronic components!
Caution!
Risk of burns from the solenoid valve as a result of long switch-
on time and high ambient temperature
Risk of burns from the solenoid valve
► Allow to cool before dismantling.
Carry out the following steps:
1.
Undo the connector of the solenoid valves at the evaluation electronics (43)
2.
Undo the screws (66) and separate the solenoid valves (63) from the
pneumatic block (8).
3.
Undo the screws (66) and, if present, separate the valve plate (65) from the
pneumatic block (8).
®
Done
Hint!
Fit the solenoid valves and valve plate in reverse order.