Caution!
Risk of burns from the solenoid valve as a result of long switch-
on time and high ambient temperature
Risk of burns from the solenoid valve
► Allow to cool before dismantling.
Carry out the following steps:
1.
Undo the connector of the solenoid valve at the evaluation electronics (43)
2.
Undo the screws (66) and separate the solenoid valve (63) from the base (5).
®
Done
Hint!
Fit the solenoid valves and valve plate in reverse order.
Tighten the screws (66) to a max. tightening torque of 1 Nm.
10.5.4 Removing the Solenoid Valves and the Control Plate (2-PV variant)
Fig.32
Requirement:
•
Only use solenoid valves specified in chapter “Technical data”.
Hint!
In order to avoid or minimize the possibility of damage from
electrostatic discharge:
- Observe the requirements of DIN EN 61340-2-1 and 5-2.
- Be careful not to touch the electronic components!
Maintenance
Dismantling the Control Top into its Components
430BAL014912EN_3
64
25.01.2024
Содержание FLOWVENT
Страница 83: ...Appendix 430BAL014912EN_3 25 01 2024 83...
Страница 84: ......