5.5
Switching point tolerances and signal output
5.5.1
Switching point tolerances
Fig.12:
DIP switch setting for valves without air
support.
Fig.13:
DIP switch setting for valves with air
support.
Signal processing
DIP 2
DIP 3
DIP 4
Tolerance
Valve type
0
0
0
0.7 mm
Seat valve*
0
1
1
1.0 mm
Valves with air support (D33+L)
* Factory setting
Hint!
Only use the DIP switch configurations shown. Further positions lead
to non-intended use.
5.5.2
Signal output
Main stroke - signal output
Pilot valve actuation
Valve position
DIP switch
Illumination
Feedback
PV Y1
PV Y2
PV Y3
1
Green
Yellow
S1
S2
0
0
0
not actuated
0
1
0
1
0
1
0
0
Main stroke / stroke in S1 tolerance
0
1
0
1
0
1
0
0
Main stroke / stroke movement
0
0
1Hz
0
0
1
0
0
main stroke / stroke in S2 tolerance
0
0
1
0
1
0
0
0
main stroke / stroke in S2 tolerance
0
0
1
0
1
0
0
0
Main stroke / stroke movement
0
1Hz
0
0
0
0
0
0
not actuated
0
1
0
1
0
Lower lift stroke - signal output
Pilot valve actuation
Valve position
DIP switch
Illumination
Feedback
PV Y1
PV Y2
PV Y3
1
Green
Yellow
S1
S2
0
1
0
lower lift stroke actuated
0
1
0
1
0
Technical data
Switching point tolerances and signal output
430BAL014912EN_3
25.01.2024
31