6.5.1
Colour Changeover
The "colour changeover" function allows you to swap the colour from green to
yellow or yellow to green for the following visualizations: valve in non-actuated
position, valve in actuated position and travel
Carry out the following steps:
1.
Disconnect the control top from the power supply.
Switch DIP 1 from position 0 to position 1.
Switch the power supply back on.
®
Done.
Hint!
When the colours are swapped, the feedback signals are also
swapped!
6.5.2
Illuminated dome
Fig.24
Key
Position
Description
1
Cap
3
Illuminated dome
The following statuses are visualized by the illuminated dome:
•
LED green, steady light: non-actuated position of the non-actuated process
valve reached.
•
LED green, steady light with yellow flashing light: non-actuated position saved
or actuated position not yet reached after main stroke (green 750 ms/ yellow
250 ms).
Assembly and installation
Visual Display
430BAL014912EN_3
46
25.01.2024