5.
For optional version with proximity
switch holder (C):
5.1
Screw the mounting for the
proximity switch (C) into the ac-
tuator using the jaw wrench on
the wrench flat surface (C3).
5.2
Screw the switch bar (139) into
the mounting for proximity
switch (C) on the wrench flat
surface (139.1) using a jaw
wrench (a/f 17).
®
Observe torques, see table ‘Tighten-
ing torques’.
.
C2
C
C1
139
139.1
C3
6.
Press the bearing (2) into the lantern
(9).
7.
Place the seal disk (3) with the O-ring
(5) and seal ring (1) into the housing.
8.
Place the lantern (9) onto the housing
and mount the hinged clamp (43) be-
tween the housing and the lantern.
®
Observe torques, see table ‘Tight-
ening torques’.
.
9.
Place the seat ring (33) with the O-
ring (5) into the housing.
10.
Screw valve disk (15) with the V-ring
(7) into actuator and tighten using
jaw wrench at wrench flat surface
(15.1). To do this, affix with a belt
wrench.
®
Observe torques, see table ‘Tight-
ening torques’.
.
9
2
3
43
1
5
15
7
7
33
5
5
15.1
Þ
The valve insert is assembled from individual parts.
9.6 Installing the valve - 81 / 128
Содержание ECOVENT
Страница 6: ...6 128 Table of Contents 0000000607 002 EN GB...
Страница 9: ...1 4 Declarations of conformity 1 4 Declarations of conformity 9 128...
Страница 12: ...12 128 1 4 Declarations of conformity 0000000607 002 EN GB...
Страница 20: ...20 128 2 10 Emergency measures 0000000607 002 EN GB...
Страница 40: ...40 128 5 5 Checking the pneumatic connection 0000000607 002 EN GB...
Страница 44: ...44 128 7 3 Shutdown 0000000607 002 EN GB...
Страница 106: ...106 128 9 7 Maintenance 0000000607 002 EN GB...
Страница 111: ...Spare parts list shuttle valve 221ELI011013EN_9 14 03 2023 2 Fig 3 with control top T VIS 12 2 Spare parts list 111 128...
Страница 120: ...120 128 12 2 Spare parts list 0000000607 002 EN GB...
Страница 127: ...13 2 List of abbreviations 127 128...