1.
Depressurize the actuator by deacti-
vating the solenoid valve Y1 at the
manual operation element S.
®
The valve disk is lowered.
The valve insert is pushed out of
the housing.
2.
Unscrew the screws (B11) of the half-
rings (B12) using a hex key, size 3,
and remove the half-rings (B12).
3.
Lift off the control top (B), also refer
to the operating instructions for the
"T.VIS control top".
4.
Pull the valve insert out of the hous-
ing
5.
Unscrew and remove switch bar (1)
with a jaw wrench.
6.
Unscrew installation base (198) with
an articulated face spanner. To do
this, affix with a belt wrench.
1
B12
B
B11
B12
B11
198
Þ
The valve is now separated from the housing.
9.5 Removing the valve - 69 / 128