Fig.19:
Removing actuator and internal assembly
®
Internal assembly and actuator are now separated from the housing.
10.7.2 Installing the valve
Tools required:
•
Hex socket key
Carry out the following steps:
1.
Install the valve in the reverse order of disassembly, see Section 10.7.1,
Page 36.
!
Note “Torques for clamps” table, see Section 10.7.3, Page 38
2.
Test the function of the valve after installing.
!
Every possible position must be activated and held for 3-5 seconds to
assure proper assembly and sealing.
®
The valve has been assembled.
10.7.3 Torques for clamp
Clamp screw thread size
Recommended torque [Nm]
M6
10
M8
20
10.8