Fig.37:
Fastening the assembly spring
®
The assembly spring moves out of the hole when it reaches the slot in the
cylinder and actuator base was turned further?
–
Continue to turn the actuator base counter-clockwise using the
flexible
head spanner
until the hole is again located underneath the position pin of
the assembly spring and the pin can be pressed in again with the
slotted
screwdriver
.
5.
Position the compressed air connection centrally over the slot in the cylinder.
Fig.38:
Placing the air connection
®
Assembly spring has been fitted.
®
Actuator PA80 - PA255 has been assembled.
10.11
Maintenance
Well-planned maintenance is essential to ensure a long service life of the valve.
Observe the following maintenance intervals. Prepare maintenance activities
well:
•
Keep a maintenance log for the valve.
•
Use the statistical analyses for your plant to plan maintenance intervals.
Only allow qualified maintenance staff to carry out maintenance work.
Hint!
Prior to any work on the open valve, ensure that it has stopped
operation, see Section 10.5, Page 35.
The following information and values are based on the experience of GEA Flow
Components and apply for installations working in 2-shift operation.
Maintenance
Maintenance
430BAL011926EN_1
30.08.2019
47