List of tools (in alphabetical order)
Tool
Figure
Intended Purpose
Material Number
GEA Aseptomag AG
Vice
with soft jaws or
equivalent protective
jaws
Fig.15
For divisible internal
assemblies and
actuators
--
Shut-off valve Ø 6 mm
Fig.16
Inspection of metal
bellows
9999.10091
10.5
Prior to disassembly
Prerequisite:
•
Make sure that while work is being performed on the open valve no process is
in operation in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse, and also depressurize them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
®
Disassembly has been prepared.
10.6
Disassembling and assembling the positioner
Aseptomag
®
Control valves can be equipped with various valve controllers, which
must be handled in accordance with the connection diagram and the instructions
in the respective operating manual.
For each of the listed positioners there is a specially designed mounting kit,
whose disassembly / assembly is explained in a separate manual. These
additional documents are provided upon request by GEA Aseptomag, see
Section 10.6.1, Page 36.
Maintenance
Prior to disassembly
430BAL011926EN_1
30.08.2019
35