![GE Telligence Patient-Staff Communications System Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/ge/telligence-patient-staff-communications-system/telligence-patient-staff-communications-system_operation-manual_132154042.webp)
Chapter 3
Using staff consoles and annunciators
36
Telligence Patient-Staff Communication System Operation Manual
Visual cues
Setting a call reminder triggers visual cues, as well:
• The Remind tab on staff consoles and annunciators flashes until
you view the Reminder screen.
• The number of active reminders is shown on the Reminders tab.
• Corridor lights and zone lights slowly flash in the color
associated with the highest staff level priority reminder until the
call has been canceled.
When nonemergency calls are received, both the active call and
the active reminder are shown.
When any of the top four call
priorities is received, however, no reminders are shown. Only
the emergency call is represented.
You can place calls on reminder without answering the calls,
assigning them up to three staff levels (RN, LPN, and aide). Only one
reminder is created and only one recall (to the Call screen) occurs
for a call on reminder (each time it returns from the Reminders
screen), even if all three staff level priorities have been set.
By default, nurse calls with priorities higher than normal but lower
than urgent are automatically placed on reminder, with red (RN)
staff level priorities, at the time that staff members answer the calls.
Setting call reminders
To remind yourself of something that needs to be done in a
particular room, you can select the room and set a location
reminder. This lists the reminder on the Reminders screen, and
starts a timer. When the timer expires, the reminder is displayed on
the Call screen. The dome light for the room flashes. The default
priority for a room location reminder is staff normal.
Manually setting reminders
For nurse calls on the Call, Audio, and Room List screens, staff
members use the Set Reminder window not only to place calls in the
reminder list, but also to assign staff level priorities to the calls.
When calls are manually set on reminder, or when additional staff
level priorities need to be placed on nurse call reminders already in
the Remind list, staff members use the Set Reminder window to
assign them one or more of these staff level priorities:
• Red: The highest staff level priority, RN.
• Amber: The middle staff level priority, LPN.
• Green: The lowest staff level priority, aide.
Содержание Telligence Patient-Staff Communications System
Страница 6: ...iv Telligence Patient Staff Communication System Operation Manual ...
Страница 14: ...Chapter 1 General information 8 Telligence Patient Staff Communication System Operation Manual ...
Страница 94: ...Chapter 4 Patient stations 88 Telligence Patient Staff Communication System Operation Manual ...
Страница 122: ...Chapter 5 Staff duty stations 116 Telligence Patient Staff Communication System Operation Manual ...
Страница 136: ...Telligence Patient Staff Communication System Operation Manual 130 ...