– 74 –
Hot Surface Indicator Light Assembly
The hot surface indicator lights are contained in an
assembly located under the cooktop.
Each hot surface indicator light is controlled by the
thermal limiter attached to the radiant element. (See
Radiant Heating Elements
.)
The hot surface indicator light assembly is held
to the underside of the cooktop with 2 notches
on the left side and 2 tabs on the right side of the
assembly.
To remove the hot surface indicator light assembly,
it is necessary to raise and support the cooktop (See
Cooktop Assembly
.), and to mark and disconnect the
wiring from the assembly. The assembly can then
be released by using a small
fl
at-blade screwdriver
to press the 2 tabs towards the center of the
assembly while lifting the right side of the assembly
out of the cooktop.
Tab
Tab
Flat-Blade Screwdriver
White/Yellow
White/Orange
White/Purple
White/Blue
White/Red
White/Brown
Wire to Terminal Location
To remove a radiant heating element:
1. Remove the cooktop assembly. (See
Cooktop
Assembly
.) Place the cooktop upsidedown on a
protective surface.
Caution
: Routing of the wires is extremely critical.
Care must be taken to ensure the wires are routed
exactly the way they were originally.
2. Mark and remove the wires to the element.
Note the location and orientation of the element to
its target location on the cooktop. Mark the location
of the retention springs where they attach to the
element.
3. Release the retention springs that hold the
element to the cooktop.
Clip
Note:
When installing a radiant element, make sure
the element is
fi
rmly pressed against the glass and
aligned in the target area.
Thermal Limiter Switch
Clip