Note:
On the 11-in. element, the choke must be
removed and transferred to the replacement
element. The choke must be attached at the same
location on the wires and secured with a plastic wire
tie.
Choke
Plastic Wire Tie
Warming Zone Element
• The warming zone element operates on
240 VAC.
• The element is rated at 100 watts, has an
approximate resistance value of 550
, and
draws approximately 0.43 amps.
• Warming zone element operation is controlled
by RPSM duty cycling algorithms. See table
below.
To remove the warming zone element:
1. Remove the aluminum plate. (See
Aluminum
Plate
.)
2. Place the aluminum plate element side up on a
protective surface.
3. Disconnect the wires from the warming zone
element.
Note:
The warming zone element is locked into
cutouts in the aluminum plate using 2 tabs. To
remove the element, it is necessary to
fi
rst position
the tab, located at the 3 o'clock position, into the
release notch.
4. Carefully grasp the outer portion of the element
and rotate it counterclockwise 1 inch until it
reaches the stop position, and then lift the
element from the aluminum plate.
SETTING
TIME VOLTAGE APPLIED
Hi
79%
Medium
54%
Lo
30%
Notch
Tab
Disconnect
Element
Connection
Element
Connection
Sensor
Connection
Tab
Tab
9. Use
a
fl
at blade screwdriver to press the lock
tab inward, and then lift the element sensor
connector from the generator board.
10. Extract the element wiring from the wire entry in
the aluminum plate.