![GE PHS925ST1SS Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/ge/phs925st1ss/phs925st1ss_technical-service-manual_2201225063.webp)
– 63 –
3. Lift the cooling fan and disconnect the wire
harness.
Disconnect
FAD
The FAD is a low voltage thermal switch. It is
attached with two 1/4-in. hex-head screws to
a bracket that is attached to the control panel
support.
The FAD disconnects the common
(yellow) of the lock logic circuit when the control
compartment area gets too hot or the cooling fan
fails. The FAD will open at 230°F
and is resetable.
The FAD is active during all operations.
Warming Drawer Element
Model PHS925
•
The warming drawer element is rated at 400
watts, has an approximate resistance value of
36
, and draws approximately 3.3 amps.
• The element is located on the
fl
oor of the
warming drawer compartment. The element
terminals are located behind the back wall.
To remove the warming drawer element:
1. Disconnect power to the range.
2. Remove the two 1/4-in. hex-head screws that
attach the element to the back wall.
3. Using
a
fl
at blade screwdriver, lift the tabs on
each of the 2 clips and remove the element from
the clips.
Clip
3. Carefully pull the warming drawer element
towards the front of the oven.
4. Disconnect the wires from the warming drawer
element.
Warming Drawer Temperature Characteristics
Hi
Warmer On Time
100
seconds
Warmer Off Time
35 seconds
100% First Rise On Time
900
seconds
Standard Warmer On Time
80 seconds
Warmer Off Time
50 seconds
100% First Rise On Time
850
seconds
Lo
Warmer On Time
100
seconds
Warmer Off Time
142
seconds
100% First Rise On Time
800
seconds
Warming drawer temperatures are controlled by
duty cycling algorithms.
Low Temperature = 165° +/- 25°F.
Standard Temperature = 175° +/- 25°F.
High Temperature = 180° +/- 25°F.