– 29 –
Control Panel
The control panel contains the main logic board and
the glass touch controls.
To remove the control panel:
1. Place a protective cover on the main top.
2. Remove the two T-15 Torx screws, (1 on each
side), that attach the control panel to the range.
4. Disconnect the 2 (PHS925) or 3 (PS978) range
wire harnesses from the main logic board
and place the control panel face down on the
protective surface.
Control Panel
Main Logic Board
The main logic board is located inside the control
panel. The main logic board is held to the control
panel with two 1/4-in. hex-head screws on the right
side and 2 tabs on the left side. The glass touch
panel assembly plugs into the main logic board.
To remove the main logic board assembly:
1. Remove the control panel. (See
Control Panel
.)
2. Disconnect the touch panel ribbon connectors
from the main logic board assembly.
4. Slide the main logic board to the right.
Note:
Before connecting power to the replacement
main logic board, transfer the model selector,
located at J201, to the replacement main logic
board. (See
Circuit Boards Connector Locator Views
.)
Disconnect
3. Remove the two 1/4-in. hex-head screws that
attach the right side of the main logic board to
the control panel.
3. Lift and rotate the control panel towards the
front of the range.
Disconnect
Disconnect
PHS925 shown