CHAPTER 2: GETTING STARTED
GETTING STARTED
MULTINET4 MULTI-PORT SERIAL SERVER & MANAGED SWITCH – INSTRUCTION MANUAL
2–11
FIGURE 2–9: DIN Rail Mounting - Dimensional Drawing
2.3.2
Connecting Facility Power
The Multinet4 comes in either high or low voltage models. The unit does not have a power
on/off switch and is active when the power is connected.
ELECTRICAL WARNING:
Always ensure that the ground connection is made prior to
connecting facility power to the Multinet4. The ground provides a protective circuit
connection to ground in cases of transients and power surges. Connect the facility power
to a DC or AC unit as described in the following sections.
2.3.2.1 Making the Ground and Power Connections
The Multinet4 provides a hardened DC or AC power supply for industrial applications and/
or hostile environments. The ground lug and power supply connector are located on the
rear of the unit as shown in the figure below.