Design Guide
5
36" Frame to
Frame Width
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Case Depth
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 24” Minimum for Standard
Installation
The unit will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
Cutout Depth Beneath a Soffit:
When installed beneathh a soffit, the soffit cannot
exceed the 24” installation depth shown. The top case
trim overlaps the bottom of the soffit.
The Cutout Depth Must Be 26-3/16” For Flush
Installation
Wooden cleats are required for flush installation. See
Side Cleats on page 11.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply
is required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the
floor or back wall. The water line should be 1/4” O.D.
copper tubing or GE QuickConnect
™
kit between the
cold water line and water connection location, long
enough to extend to the front of the unit. Installation
of an easily accessible shut-off valve in the water line
is required.
DIMENSIONS AND CLEARANCES
* Shipping height. The
product can be adjusted
to fit into a cutout that
is 84-1/2” max. height.
Note that the top case
trim at the front is 1/2”
higher and will overlap
upper cabinetry or sof-
fit. Use leveling legs and
wheels for a maximum 1”
height adjustment.
Product Clearances
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Order WX14X99 door stop for precise settings between
90° and 130°.
130° Door Swing
90° Door Swing
Allow 25” minimum clearance for a full 130° door
swing. Allow 15” for pan removal.
For a 90° door swing, allow 4” minimum clearance to
a wall for framed and stainless steel models. Allow 5”
minimum clearance for professional models. If the 90°
doorstop position is used, pan access is maintained but
pan removal is restricted.
See illustrations pages
6 and 7
to determine door swing
interaction with adjacent cabinets or countertops.
*
4
”
stainless and trimmed
models. 5
”
Pro models.
*For standard installation, the finished cutout width
must be 35-1/2”.
*For flush mount installation, the finished cutout width
must be 39”.
115° Door Swing
Содержание Monogram ZIRS360NNLH
Страница 30: ...Notes 30...
Страница 31: ...Notes 31...