10
D0404SG0_B
KTD-404 Controller Keypad Installation and Operations Guide
Camera Site Access
System Size
Step 3)
The CLEAR MEMORY option will erase all data in the controller keypads
nonvolatile memory and reload factory default values.
To clear the keypads memory, press
1
. The display will automatically advance
to the menu shown in Figure 11.
If the CLEAR MEMORY function is not to be used, press
0
and go to Step 5.
Step 4)
This menu offers a safety check. If a
3
is entered, the controller keypads
memory will be reloaded with factory default values. If a
0
is entered, there will
be no change. The display will automatically advance to the next menu.
Step 5)
This menu is used to set the system size. Use the numerical keys to enter the
largest camera number, largest monitor number, largest multiplexer number, and
largest preset number in the system. Maximum entries are: cameras-511,
monitors-64, multiplexers-64, and presets-63.
Press
seq
to advance to the next column, or move the joystick left or right to switch
between columns. Once all entries are made, the display will automatically
advance to the next menu.
Step 6)
This menu is used to deny or permit the controller keypads access to certain
camera sites. Press
0
to deny access or
1
to permit access. After each
selection, the next camera number will appear. Move the joystick up or down to
switch between cameras. When done, press
seq
to advance to the next menu.
Figure 13: Camera Site Access Display
CAMERA 000 ACC=YES
0=NO 1=YES SEQ=NEXT
Figure 12: System Size Display
SYST SIZE (CAMERAS)
511 64 64 63 SEQ=NEXT
Figure 11: Second Clear Memory Display
ARE YOU SURE?
0=NO 3=YES SEQ=NEXT
Clear Keypad Memory
Figure 10: Clear Memory Display
CLEAR MEMORY?
0=NO 1=YES SEQ=NEXT
Helpful Hint:
Pressing the
seq
key will forward you through programming without changing
the set parameters.