background image

WARNING 

RISK OF FIRE

• To reduce the risk of severe injury or death, follow all installation 

instructions.

• 

&ORWKHVGU\HULQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU

•  Install the clothes dryer according to these instructions and in accordance 

with local codes.

•  This dryer must be exhausted to the outdoors.
•  Use only rigid metal 4” diameter ductwork inside the dryer cabinet and use 

only UL approved transition ducting between the dryer and the home duct.

• 

'2127LQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,I
ÀH[LEOHPHWDOVHPLULJLGRUIRLOW\SHGXFWLVLQVWDOOHGLWPXVWEH8/OLVWHG

and installed in accordance with the instructions found in “Connecting 

7KH'U\HU7R+RXVH9HQWµRQSDJHVRIWKLVPDQXDO)OH[LEOHYHQWLQJ

materials are known to collapse, be easily crushed, and trap lint. These 

FRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH

• Do not install or store this appliance in any location where it could be 

exposed to water and or weather.

• 

6DYH WKHVH LQVWUXFWLRQV ,QVWDOOHUV %H VXUH WR OHDYH WKHVH LQVWUXFWLRQV
ZLWKWKHFXVWRPHU

NOTE: Installation and service of this dryer requires basic 
mechanical and electrical skills. It is your responsibility to contact 

DTXDOL¿HGLQVWDOOHUWRPDNHWKHHOHFWULFDOFRQQHFWLRQV

Installation

Instructions

Electric Dryer

02

Questions on Installation? Call: 800.GE.CARES (US)

or visit our Web site at: www.GEAppliances.com (US)

BEFORE YOU BEGIN

Read these instructions completely and 
carefully.

• IMPORTANT-

 Save these instructions 

for local inspector’s use.

• IMPORTANT-

 Observe all governing 

codes and ordinances.

• Note to Installer -

 %H VXUH WR OHDYH WKHVH

instructions with the customer.

•  Note to Customer -

 Keep these instructions 

with your Owner’s Manual for future 
reference.

• 

%HIRUHWKHROGGU\HULVUHPRYHGIURPVHUYLFH

or discarded, remove the dryer door.

•  Service information and the wiring diagram 

are located in the control console.

•  Do not allow children on or in the appliance. 

Close supervision of children isnecessary 
when the appliance is used near children.

• Install the dryer where the temperature is 

DERYHƒ)IRUVDWLVIDFWRU\RSHUDWLRQRIWKH

dryer control system.

• Product failure due to improper installation 

is not covered under the Warranty.

TOOLS YOU

WILL NEED

PHILLIPS SCREWDRIVER

SLIP JOINT PLIERS

LEVEL

FLAT BLADE SCREWDRIVER

MATERIALS YOU WILL NEED

GLOVES

SAFETY

GLASSES

DRYER POWER

CORD KIT

(NOT PROVIDED

WITH DRYER)

4" DUCT

CLAMPS (2)

OR

4" SPRING

CLAMPS (2)

EXHAUST

HOOD

3/4" STRAIN

RELIEF

UL RECOGNIZED

4" DIA. METAL

ELBOW

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

DUCT TAPE

UL RATED 
120/240V,30A       
WITH 3 OR 4 PRONGS. 
IDENTIFY THE PLUG 
TYPE AS PER THE 
HOUSE RECEPTACLE 
BEFORE PURCHASING 
LINE CORD. 

4” COVER PLATE (IF NEEDED

(KIT WE1M454)

Minimum Clearance Other Than Alcove or Closet Installation

0LQLPXPFOHDUDQFHWRFRPEXVWLEOHVXUIDFHVDQGIRUDLURSHQLQJDUHLQFOHDUDQFHERWKVLGHVLQIURQWDQGLQUHDU

Consideration 

must

 be given to provide adequate clearance for installation and service.

234D2008P002

31-16726-1

  

03-14 GE

Printed in Mexico

Содержание Electric Dryer 02

Страница 1: ...instructions for local inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer H VXUH WR OHDYH WKHVH instructions with the customer Note to Customer Keep these instructions with your Owner s Manual for future reference HIRUH WKH ROG GU HU LV UHPRYHG IURP VHUYLFH or discarded remove the dryer door Service information and the wiring diagram are located in the control c...

Страница 2: ...EORFN PDUNHG 1 7 Attach ground wire of power cord with the green JURXQG VFUHZ KROH DERYH VWUDLQ UHOLHI EUDFNHW 7LJKWHQ DOO WHUPLQDO EORFN VFUHZV VHFXUHO 8 Properly secure power cord to strain relief 9 Reinstall the cover INTERNAL DUCT OPENING CHECK THAT EXHAUST HOOD DAMPER OPENS AND CLOSES FREELY WALL TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES AND BREAKING TH...

Страница 3: ...minal of block and to green ground screw on cabinet UHDU 7LJKWHQ DOO WHUPLQDO EORFN VFUHZV VHFXUHO 7 Properly secure power cord to strain relief 8 Reinstall the cover WARNING NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK I UHTXLUHG E ORFDO FRGH LQVWDOO H WHUQDO JURXQG QRW SURYLGHG to grounded metal cold water pipe or other established ground determined by a qualified electrician Wire according t...

Страница 4: ...RQV DGG RQH HOERZ WR WKH FKDUW 7KH WRWDO YHQW V VWHP OHQJWK LQFOXGHV DOO WKH VWUDLJKW SRUWLRQV DQG HOERZV RI WKH V VWHP WUDQVLWLRQ GXFW LQFOXGHG EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife 7HUPLQDWLRQ VKRXOG SUHVHQW PLQLPDO UHVLVWDQFH WR WKH H KDXVW DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR PDLQWHQDQFH WR SUHYHQW cloggin...

Страница 5: ...mmended Rigid metal transition ducts reduce the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT I ULJLG PHWDO GXFW FDQQRW EH XVHG WKHQ 8 OLVWHG ÀH LEOH PHWDO VHPL ULJLG GXFWLQJ FDQ EH XVHG LW 1HYHU LQVWDOO ÀH LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU other enclosed spaces 7RWDO OHQJWK RI ÀH LEOH PHWDO GXFW VKRXOG QRW H FHHG IHHW P DUCT TAPE OR DUCT CLAMP DUCT TAPE...

Страница 6: ...HQGHG VHH LOOXVWUDWLRQV EHORZ OERZV DOORZ WKH GU HU WR VLW FORVH WR WKH ZDOO without kinking and or crushing the transition duct PD LPL LQJ GU LQJ SHUIRUPDQFH Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT In special installations it may be necessary to connect WKH GU HU WR WKH KRXVH YHQW XVLQJ D ÀH LEOH PHWDO IRLO W SH GXFW 8 OLVWHG ÀH LEOH PHWDO IRLO W...

Страница 7: ...tured home 7KH YHQW GXFW PDWHULDO 0867 0 7 Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent See section 2 for electrical connection information 8 TAB LOCATION ADDING NEW DUCT GARAGE INSTALLATION IF ALLOWED BY LOCAL CODES U HUV LQVWDOOHG LQ JDUDJHV PXVW EH HOHYDWHG LQFKHV FP DERYH WKH ÀRRU 9 Through the rear opening locate the tab in the mi...

Страница 8: ...er internal duct and elbow as shown above EXHAUST CAN BE ADDED TO LEFT OR RIGHT SIDE DUCT TAPE DUCT TAPE CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET SIDES AND BOTTOM EXHAUST Connect standard metal elbows and ducts to complete WKH H KDXVW V VWHP RYHU EDFN RSHQLQJ ZLWK D SODWH LW 0 DYDLODEOH IURP R...

Страница 9: ...RGRV ORV códigos y ordenanzas vigentes Nota al instalador VHJ UHVH GH GHMDU HVWDV instrucciones con el consumidor Nota al consumidor Mantenga estas instrucciones con el Manual del Propietario para referencia futura QWHV GH TXH OD VHFDGRUD DQWLJXD VHD UHWLUDGD GHO VHUYLFLR R HOLPLQDGD TXtWHOH OD SXHUWD Lainformaciónsobrereparacionesyeldiagrama del cableado se encuentran en la consola de control 1R ...

Страница 10: ...D WLHUUD RUL FLR VREUH HO VRSRUWH GH DOLYLR GH WHQVLyQ MXVWH SRU UPHPHQWH WRGRV ORV WRUQLOORV GHO EORTXH WHUPLQDO MXVWH ELHQ HO FDEOH GH HQHUJtD DO DOLYLR GH WHQVLyQ 9 Vuelva a instalar la tapa ABERTURA DE CONDUCTO INTERNA PARED VERIFIQUE QUE EL REGULADOR DE TIRO DE LA CAMPANA DE SALIDA SE ABRA Y CIERRE LIBREMENTE INCLINE LA SECADORA DE COSTADO Y QUITE LAS ALMOHADILLAS DE ESPUMA PARA ENVÍO TOMÁNDO...

Страница 11: ...D ORV WRUQLOORV H WHUQRV GHO EORTXH WHUPLQDO PDUFDGR RQHFWH HO FDEOH QHXWUDO EODQFR DO FHQWUR GHO EORTXH WHUPLQDO PDUFDGR 1 VHJ UHVH GH TXH OD FLQWD GH FRQH LyQ D WLHUUD HVWp FRQHFWDGD D OD WHUPLQDO QHXWUDO FHQWUDO GHO EORTXH DO tornillo verde de conexión a tierra de la parte trasera del JDELQHWH MXVWH SRU UPHPHQWH WRGRV ORV WRUQLOORV GHO EORTXH WHUPLQDO MXVWH ELHQ HO FDEOH GH HQHUJtD DO DOLYLR GH...

Страница 12: ...VLEOH GHO VLVWHPD GH HVFDSH Dos codos de 45 deberán ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla D ORQJLWXG WRWDO GHO VLVWHPD GH HVFDSH LQFOX H WRGDV ODV SRUFLRQHV UHFWDV WRGRV ORV FRGRV GHO VLVWHPD LQFOX HQGR HO GXFWR GH transición 4 DIA 4 4 DIA 4 DIA 2 1 2 LONGITUD MÁXIMA RECOMENDADA Tipos de campana de salida Recomendado 90 Pies 60 Pies 45 Pies 35 ...

Страница 13: ...IZAR LAS OBSTRUCCIONES DE LA SALIDA LVWHQ RSFLRQHV P OWLSOHV GH LQVWDODFLyQ Seleccione el método más apropiado para su instalación RV FRQGXFWRV PiV ODUJRV DFXPXODQ SHOXVD OR TXH JHQHUD XQ riesgo potencial de incendio 1XQFD LQVWDOH XQ OWUR GHQWUR R VREUH HO FRQGXFWR GH VDOLGD VWR SURYRFDUi OD DFXPXODFLyQ GH SHOXVDV OR TXH JHQHUD un riesgo potencial de incendio 1R DUPH OD UHG GH FRQGXFWRV FRQ VXMHFL...

Страница 14: ...RQGXFWR VREUH REMHWRV D ODGRV CONDUCTODETRANSICIÓNDEMETALFLEXIBLE SEMI RÍGIDO APROBADO POR UL En instalaciones especiales puede ser necesario conectar la secadora a la ventilación doméstica utilizando un conducto GH PHWDO ÀH LEOH WLSR SDSHO GH DOXPLQLR 3XHGH XWLOL DUVH XQ FRQGXFWR GH PHWDO ÀH LEOH WLSR SDSHO GH DOXPLQLR DSUREDGR SRU 8 6Ï 2 HQ LQVWDODFLRQHV HQ ODV TXH QR SXHGHQ XVDUVH FRQGXFWRV GH ...

Страница 15: ...r la sección 2 sobre información sobre conexiones eléctricas 8 INSTALACIÓNENGARAJE SIPERMITIDO POR LOS CODIGOS LOCALES 6HFDGRUDV LQVWDODGDV HQ JDUDJHV GHEHQ VHU HOHYDGDV SXOJDGDV FP GHO QLYHO GHO SLVR 9 A través de la abertura trasera ubique la lengüeta en el medio de la base del aparato Levante la lengüeta hasta alrededor de 45 utilizando un destornillador de lados planos GIRE LA LENGÜETA HASTA 4...

Страница 16: ...ORFDO RORTXH OD VHFDGRUD HQ VX XELFDFLyQ QDO PRECAUCIÓN Las juntas del conducto interno deben sujetarse con cinta caso contrario pueden separarse y provocar un riesgo de seguridad PLACA KIT WE1M454 5 675 68 18 92 3 5 72 3 5 5 5 6 127 21 6 352 8 726 03257 17 6 Por favor vaya a www GEAppliances com o HQYLDU SRU FRUUHR VX WDUMHWD GH LQVFULSFLyQ 3DUD SUHJXQWDV VREUH OD LQVWDODFLyQ OODPH DO 88 R DQDGi ...

Отзывы: