background image

1

TECHNICAL SPECIFICATIONS

Motor 

Heater 

Total

Input

ITEM CATEGORY

Operating Voltage 

Output  Warm Air Volume 

Output  Warm Air Temp 

Output Air Speed

Motor Type 

Motor Thermal Protection 

Heater Element 

Heater Thermal Protection 

Drying Time 

Circuit Operation 

Sensor Range

Timing Protection 

Timing Duration 

Output  Air Nozzle

Sound Level

Drip Proof

Cover Type 

Cover Finish 

Net Weight 

Shipping Weight 

Unit Size 

PERFORMANCE DATA

220-240VAC, 50/60Hz, 10A, 2.4KW  

255

m³/h

 [150CFM]

60

°

C  140

°

F  at ambient T = 25

°

C  77

°

F

[

[

47mph 

(

69ft/s) 

[

21m/s 

{75

.6km/h

}

]

200W, 5500rpm, brush type, dual ball bearings 

Auto resetting thermostat turns unit off at 105

°

C  221

°

F

[

Less than 20 seconds 

Infrared automatic, self adjusting

60 seconds auto shut off

4 seconds delayed turn off after last sensor read 

Heavy-Duty chrome plated zinc die casting

Formed steel or 

stainless steel,

 1.6mm, [1/16"] 

 thick

Powder coating white on steel or bright or satin on stainless steel

6.2kg [13.7lbs]

7.0kg [15.4lbs]

300mm W x 251mm H x 219mm D [11-13/16" x 9-7/8" x 8-5/8"] 

2200W @ 220-240VAC, nichrome 27.2  

Ω

100mm to 250mm [4" to 10"], adjustable; standard 170mm ± 20mm [7"]

www.asijdmacdonald.com.au

Auto resetting thermostat turns unit off at 65

°

C  149

°

F , resets at 50

°

C  122

°

F

[

]

[

]

HDABWHTSG - 

white with silver gloss nozzle

HDABWHTPC - 

white with polished chrome nozzle

HDABPSSPC  - 

polished stainless steel with polished chrome nozzle

HDABWHTSC - 

white with satin chrome nozzle

HDABSSSSC - 

 satin stainless steel with satin chrome nozzle

MODEL : AUTOBEAM

63.4

dB 

@

 

2m

IPX3

300

(11-13/16")

219

(8-5/8")

251

(9-7/8")

PLEASE CAREFULLY READ THROUGH THIS MANUAL BEFORE USING THE PRODUCT. 
OBSERVING ALL SAFETY INFORMATION, WARNINGS AND CAUTIONS WILL PROTECT 
YOURSELF AND OTHERS. PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE.

Operating Instructions and Parts Manual 

Hand Dryer

Surface-mounted Push Button hand dryer 

VAC

220

230

240

Vac

220

230

240

Inrush A(W)

1.14 (252)

1.18 (276) 

1.24 (300)

Operating  A(W)

0.76 (168)

0.80 (184)

0.83 (200)

8.40 (1848)

8.78 (2020) 

9.17 (2200)

Vac

220

230

240

Inrush A(W)

 

 

9.54 (2100)

 

 

9.96 (2296) 

10.41 (2500)

Operating A(W)

9.16 (2016)

9.58 (2204) 

10.0 (2400)

Operating A(W)

DIM’S

mm(inch)

Summary of Contents for AUTOBEAM

Page 1: ...7 0kg 15 4lbs 300mm W x 251mm H x 219mm D 11 13 16 x 9 7 8 x 8 5 8 2200W 220 240VAC nichrome 27 2Ω 100mm to 250mm 4 to 10 adjustable standard 170mm 20mm 7 www asijdmacdonald com au Auto resetting thermostat turns unit off at 65 C 149 F resets at 50 C 122 F HDABWHTSG white with silver gloss nozzle HDABWHTPC white with polished chrome nozzle HDABPSSPC polished stainless steel with polished chrome no...

Page 2: ...rely to chassis at KO with appropriate strain relief connector not supplied 5 Attach dryer to wall For wood wall studs use 1 4 inch M6 screws at length that will ensure 1 inch 25 mm min stud penetration For masonry walls use expansion bolts or anchors for 1 4 inch M6 screws to ensure penetration 1 4 inch 6 mm deeper than anchor Shim if necessary to ensure base plate is flat against wall 6 Connect ...

Page 3: ...dren 4 7 years Children 8 10 years Children 11 13 years Children 14 16 years 50 1194 mm 47 889 mm 35 991 mm 39 1092 mm 43 1194 mm 47 Surface mounted Automatic hand dryer Circuit Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au Circuit Board Module MO2 HE2 N MO1 HE1 L Transistor Power Switch G N L Thermostat G Y Blue Brown Motor With Thermal Switch 2A Black 120 240V Black 12...

Page 4: ...oose or damaged wires Remove the blower housing Check the element for signs of burning or breakage Damaged element must be replaced If the element does not appear damaged disconnect it at the timer assembly and check element wire continuity see tech spec An open circuit indicates damage to the element wire and to the integral temperature limit control TLC Separate the TLC and test for open circuit...

Page 5: ...housing RH Thermostat TLC Motor bracket Nylon washer Motor Motor 200W 240Vac Motor brush Rubber grommet Motor Rating label 220 240Vac Terminal label Screw M4x6 headless set with 2mm hex key Screw 10 24x1 2 philips truss head Hex Nut 10 24 Self Threading Screw M4x10 philips pan head 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A0183 A0131 A0065 A0066 A0068 A0069 A0071 A0072 A0277 A0288 Screw M5x10 ...

Page 6: ...urface mounted Automatic hand dryer 1 2 3 4 5 Assembly Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au 6 7 8 9 11 12 23 34 13 14 15 16 17 18 19 20 21 22 36 24 25 26 27 28 29 31 32 33 35 37 38 39 40 41 42 10 ASI JD MacDonald Pty Ltd ...